background image

18

English

An application, such as a DAW, fails to recognize the mLAN driver (MIDI/audio).

• (For Windows) Make sure mLAN has not been turned off. On the task bar, right-click mLAN 

Manager (

), then select ON.

.......Refer to “Confirming the installation” in the Installation Guide and “mLAN 

Connection Settings” in the mLAN Graphic Patchbay Online Manual.

• Make sure the MY16-mLAN is connected to the mLAN cable and is powered on. Start mLAN 

Auto Connector or mLAN Graphic Patchbay, then re-connect the device.

.......Refer to “Confirming the installation” in the Installation Guide and “mLAN 

Connection Settings” in the mLAN Graphic Patchbay Online Manual.

• (For Macintosh) To use an iBook or PowerBook in the system, connect the MY16-mLAN-

equipped device to the Macintosh using an mLAN cable, turn on the power to the MY16-
mLAN-equipped device, then start the Macintosh.

• Make sure the mLAN settings are correct.

.......Refer to “Unable to communicate via mLAN” on page 17.

The computer processing speed is too slow.

The computer’s CPU meter indicates a heavy processing load.

Playback response is delayed.

• Make sure your computer satisfies the system requirements.

.......Refer to “System Requirements” in the Installation Guide.

• (For Windows) If you do not use the mLAN system, on the task bar right-click mLAN Manager 

(

), then select OFF (mLAN quits).

.......Refer to “Confirming the installation” in the Installation Guide.

• Try reducing the number of audio channels in mLAN Auto Connector or Graphic Patchbay.

.......Refer to “Connecting the Computer and mLAN devices via mLAN” in the 

Installation Guide and “mLAN Connection Settings” in the mLAN Graphic 
Patchbay Online Manual.

• Try increasing the latency value.

..........Refer to “Changing the Settings after Installation” in the Installation Guide.

• (For Windows) Refer to “Hints when using audio data (Windows).”

.......Refer to the Installation Guide.

• (For Windows) The condition may improve if you set “Hyper Threading” to “Disable.”
• Using mLAN Graphic Patchbay, try reducing the number of devices connected to the com-

puter.

.......Refer to “mLAN Connection Settings” in the mLAN Graphic Patchbay Online 

Manual.

• If multiple S200-compatible devices are connected to the network, connecting mLAN devices 

in mLAN Graphic Patchbay may require more time.

Inconsistency in wordclock, or unable to exit from Auto Connector 

• (For Windows) Mobile computers with Intel CPU

SpeedStep™ technology is applied for some CPU’s (CPU for notebook PC).  Please disable the 
SpeedStep™ technology when mLAN is employed.  SpeedStep™ technology changes CPU 
clock dynamically depending on the loading on the CPU to save the power consumption.

- How to disable the SpeedStep™ technology;

In almost all of the PC’s, BIOS has a function to select enabling or disabling the SpeedStep™ 
technology.  Please refer to the PC’s operating manual, or make inquiry to the PC manufac-
turer.

Содержание mLAN MY16

Страница 1: ...Owner s Manual Bedienungsanleitung Mode d emploi mLAN INTERFACE CARD MY16 mLAN English Deutsch Français ...

Страница 2: ...liminate shock hazard Turn off all peripheral devices of the host device before installation and unplug all cables connecting the host device to all peripheral devices CAUTION Always follow the basic precautions listed below to avoid the possibility of physical injury to you or others or damage to the device or other property These precautions include but are not limited to the following Do not to...

Страница 3: ...ual carefully After reading this manual please keep it available for future reference Package Contents MY16 mLAN unit Tools for MY16 mLAN CD ROM Owner s Manual this document Tools for MY16 mLAN Installation Guide If you re using the 01V If the MY16 mLAN is installed in the 01V the MY16 mLAN will operate in maximum audio input output 8 in 8 out wordclock 44 1 kHz 48 kHz only and transmission speed ...

Страница 4: ...LAN connections intuitively using a graphical user inter face From your computer you can specify the audio MIDI signal flow and make synchroni zation settings intuitively and easily the mLAN Auto Connector software makes it easy to connect mLAN devices to your computer and mLAN Graphic Patchbay lets you connect multiple mLAN devices simply by making settings on your computer screen Up to 16 channe...

Страница 5: ...394 an indus try standard high performance data communications protocol Digital music environments that do not feature mLAN require dozens of cables for vari ous devices and purposes including MIDI cables and audio cables to route MIDI and audio signals If you wish to make changes to such systems you must physically discon nect and re connect these cables For example adding another synthesizer to ...

Страница 6: ...Guide 3 Connect the computer and mLAN devices using the IEEE1394 cables See page 10 4 Turn on mLAN Manager Windows only See Confirming the installation in the Installation Guide 5 To connect a computer to a single mLAN device directly first start mLAN Auto Connector To connect a computer to multiple mLAN devices start mLAN Graphic Patchbay See page 14 6 Configure connections in mLAN Auto Connector...

Страница 7: ...e 01V the MY16 mLAN will operate in max imum audio input output 8 in 8 out wordclock 44 1 kHz 48 kHz only and transmission speed 400 Mbps Also it will be shown as MY8 mLAN in the 01V s display If you re using a 01V96 DM1000 system version earlier than 2 01 or 02R96 DM2000 system version earlier than 2 11 In order to allow it to operate as the MY16 mLAN you will need to update your device For detai...

Страница 8: ... the MY16 mLAN in your device You won t be able to change the DIP switch setting once you ve installed the MY16 mLAN If you need to change the setting turn off the power of your device remove the MY16 mLAN and then change the setting 2 Install the MY16 mLAN in your device For details refer to the owner s man ual of the device in which you re installing it Before you install the card you must power...

Страница 9: ... cable Do not connect the cables in a loop See page 17 We recommend S400 compatible IEEE1394 cables mLAN cables that are no longer than 4 5 meters B ACTIVE indicator This indicator lights up when the MY16 mLAN is operating The indicator turns off when an error occurs during an operation When you click the ID Identify button in mLAN Auto Connector or mLAN Graphic Patchbay page 14 to identify the co...

Страница 10: ...t the mLAN IEEE1394 connector on the mLAN device and IEEE1394 compati ble computer to the mLAN connector on the MY16 mLAN using IEEE1394 FireWire i LINK cables At this time you do not have to turn off the power to the mLAN device or the MY16 mLAN equipped device mLAN IEEE1394 device IEEE1394 compatible computer IEEE1394 cable IEEE1394 cable mLAN16E MY16 mLAN ...

Страница 11: ...ordclock By making an mLAN con nection between your computer and the MY16 mLAN equipped device you ll be able to transfer multiple channels of audio in realtime between your computer and the device Like example below we recommend that you use the USB cable in the opera tion of Studio Manager If you use the mLAN MIDI cable to transmit or receive MIDI operating Studio Manager may require more time 1...

Страница 12: ...data between mLAN devices simply by connecting them via IEEE1394 cables Set up and modify audio and MIDI signal patches between mLAN devices in various situations using mLAN Graphic Patchbay without physically re patching cables Like example below we recommend that you use the USB cable in the opera tion of Studio Manager If you use the mLAN MIDI cable to transmit or receive MIDI operating Studio ...

Страница 13: ...nchronization is achieved using a wordclock a clock signal that synchronizes all digital audio signals in a system In a typical digital audio system one device operates as the wordclock master and transmits a wordclock signal The other devices operate as wordclock slaves syn chronizing to the wordclock master To connect the MY16 mLAN to external devices via mLAN you must first make clock settings ...

Страница 14: ... a single mLAN device mLAN Graphic Patchbay This graphic software application enables you to manage mLAN connection settings for the connected computer and multiple mLAN devices You can immediately grasp connections in their entirety by viewing dis played mLAN system configuration graph ics You can also intuitively modify wordclock settings and audio and MIDI sig nal routing much as if you were co...

Страница 15: ...ve been exceeded Check the current band width using mLAN Graphic Patchbay and disconnect some devices if necessary Refer to Menu Bar in the mLAN Graphic Patchbay Online Manual If there is an mLAN device that supports only S200 on the mLAN network the IEEE1394 BUS bandwidth may be reduced and its limit exceeded Reduce the number of mLAN devices con nected to the network or disconnect some devices a...

Страница 16: ...t run applications such as anti virus software in the background While using the mLAN system turn off all applications that run in background If these applications remain on driver operation may become unstable and cause noise If you do not plan to use the mLAN system you can turn these applications on You can turn the mLAN driver on and off using mLAN Manager Insufficient tracks for recording or ...

Страница 17: ...vice Even if the model is the same if the actual device is different it is necessary to re enable connection by using Auto Connector and or Graphic Patchbay Refer to Connecting a Computer to an mLAN device via mLAN in the Installation Guide and mLAN Connection Settings in the mLAN Graphic Patchbay Online Manual Is there a loop connection Check the cabling and make sure none of the devices are con ...

Страница 18: ...uits Refer to Confirming the installation in the Installation Guide Try reducing the number of audio channels in mLAN Auto Connector or Graphic Patchbay Refer to Connecting the Computer and mLAN devices via mLAN in the Installation Guide and mLAN Connection Settings in the mLAN Graphic Patchbay Online Manual Try increasing the latency value Refer to Changing the Settings after Installation in the ...

Страница 19: ...sses listed below manually Ctrl Alt Delete Processes select process End process When finished start mLAN Manager to change the mLAN settings again mLANVDevice exe mLANTFamily exe mLANSoftPH exe mLANManager exe To change mLAN settings select Start All Programs Start Up then start mLAN Manager When a message such as file cannot be found appears when uninstalling Try executing the installation once m...

Страница 20: ...8Out 88 2kHz 96kHz Fs 44 1kHz 10 to 48kHz 6 88 2kHz 10 to 96kHz 6 Resolution 24bit MIDI 1In 1Out Baudrate 31 25kbps Necessary for USB connections for using Multi Port MIDI SLOT1 is available for Digital console within multi SLOTs Wordclock Transi tion Speed setting Slow Fast Specified by included mLAN Graphic Patchbay or Auto Con nector Indication LED ACTIVE Blue Host device detec tion switch 01V ...

Страница 21: ...21 English MEMO ...

Страница 22: ...AMERICA class B devices Compliance with FCC regulations does not guarantee that interference will not occur in all installations If this product is found to be the source of interference which can be determined by turning the unit OFF and ON please try to eliminate the problem by using one of the following measures Relocate either this product or the device that is being affected by the interferen...

Страница 23: ...lano Italy Tel 02 935 771 SPAIN PORTUGAL Yamaha Hazen Música S A Ctra de la Coruna km 17 200 28230 Las Rozas Madrid Spain Tel 91 639 8888 SWEDEN Yamaha Scandinavia AB J A Wettergrens Gata 1 Box 30053 S 400 43 Göteborg Sweden Tel 031 89 34 00 DENMARK YS Copenhagen Liaison Office Generatorvej 6A DK 2730 Herlev Denmark Tel 44 92 49 00 NORWAY Norsk filial av Yamaha Scandinavia AB Grini Næringspark 1 N...

Страница 24: ...n 2004 Yamaha Corporation This document is printed on recycled chlorine free ECF paper with soy ink Auf Recycling Umweltpapier gedruckt Ce document a été imprimé sur du papier recyclé non blanchi au chlore Yamaha Manual Library http www2 yamaha co jp manual english ...

Отзывы: