Dynamics Parameters
M7CL Owner’s Manual
251
Appendices
The hard and soft companders combine the effects of the compressor, expander and limiter.
The companders function differently at the following levels:
1
0 dB and higher
. . . . . . . . . . . . . . . . . . Functions as a limiter.
2
Exceeding the threshold
. . . . . . . . . . Functions as a compressor.
3
Below the threshold and width
. . . . Functions as an expander.
The hard compander has an expansion ratio of 5:1, while the soft compander has an expansion ratio of 1.5:1. The expander is
essentially turned off when the width is set to maximum. The compressor has a fixed knee setting of 2.
* The gain is automatically adjusted according to the ratio and threshold values, and can be increased by up to 18 dB.
* The OUT GAIN parameter enables you to compensate for the overall level change caused by the compression and expan-
sion processes.
This detects and compresses only the sibilants and other high-frequency consonants of the vocal.
Parameter
Range
Description
THRESHOLD (dB)
–54 to 0 (55 points)
This determines the level at which compression is applied.
RATIO
1.0:1, 1.1:1, 1.3:1, 1.5:1, 1.7:1, 2.0:1,
2.5:1, 3.0:1, 3.5:1, 4.0:1, 5.0:1, 6.0:1,
8.0:1, 10:1, 20:1 (15 points)
This determines the amount of compression.
ATTACK (ms)
0–120 (121 points)
This determines how soon the signal is compressed or expanded once the com-
pander has been triggered.
RELEASE (ms)
44.1kHz: 6 ms – 46.0 sec
48kHz: 5 ms – 42.3 sec (160 points)
This determines how soon the compressor or expander returns to the normal gain
once the trigger signal level drops below or exceeds the threshold respectively. The
value is expressed as the duration required for the level to change by 6 dB.
OUT GAIN (dB)
–18.0 to 0.0 (181 points)
This sets the compander’s output signal level.
WIDTH (dB)
1–90 (90 points)
This determines how far below the threshold expansion will be applied. The
expander is activated when the level drops below the threshold and width.
■
COMPANDER HARD (COMPANDER-H), COMPANDER SOFT (COMPANDER-S)
0dB
Input Level
Output Level
THRESHOLD
WIDTH
Parameter
Range
Description
THRESHOLD
–54 to 0 (55 points)
Threshold level at which the de-esser effect applies.
FREQUENCY
1kHz – 12.5kHz (45 points)
Cutoff frequency of the HPF used to detect the high frequencies.
■
DE-ESSER
Содержание M7CL StageMix V1.5
Страница 1: ...M7CL 32 M7CL 48 M7CL 48ES Owner s Manual EN ...
Страница 28: ...M7CL Owner s Manual 28 ...
Страница 42: ...M7CL Owner s Manual 42 ...
Страница 78: ...M7CL Owner s Manual 78 ...
Страница 114: ...M7CL Owner s Manual 114 ...
Страница 122: ...M7CL Owner s Manual 122 ...
Страница 166: ...M7CL Owner s Manual 166 ...
Страница 170: ...M7CL Owner s Manual 170 ...
Страница 196: ...M7CL Owner s Manual 196 ...
Страница 206: ...M7CL Owner s Manual 206 ...
Страница 244: ...M7CL Owner s Manual 244 ...
Страница 306: ...M7CL Owner s Manual 306 ...