8-43
–
+
ELEC
E
CHARGING SYSTEM
MEASURING THE LIGHTING COIL
OUTPUT PEAK VOLTAGE
8
Measure:
• Lighting coil output peak voltage
Below specification
→
Replace the
lighting coil.
NOTE:
Before measuring the lighting coil output
peak voltage, disconnect the rectifier/regu-
lator coupler (blue)
1
.
Lighting coil output peak voltage
Green (G) – Green (G)
r/min
Circuit
Loaded
Cranking
1,500
3,500
V
7.5
8.0
12
12
Test harness (1-pin)
YB-06788 / 90890-06788
Test harness (2-pin)
YB-06787 / 90890-06787
8276
G
G
1