[Input mode]
global configuration mode
[Description]
Sets the MIB variable sysLocation.
sysLocation is a variable that is generally used to enter the installed location of the unit.
If this command is executed with the "no" syntax, the setting is deleted.
[Example]
Set the system location as "MainOffice-1F".
SWR2311P(config)#snmp-server location MainOffice-1F
4.10.5 Set SNMP community
[Syntax]
snmp-server
community
community
ro_rw
no
snmp-server
community
community
[Parameter]
community
:
Community name (maximum 32 characters)
ro_rw
:
Access restriction
Setting value
Description
ro
Read only
rw
Write allowed
[Initial value]
none
[Input mode]
global configuration mode
[Description]
Sets the SNMP community.
Up to 16 communities can be registered.
If this is executed with the "no" syntax, the specified community is deleted.
[Example]
Set the read-only community name to "public".
SWR2311P(config)#snmp-server community public ro
Delete the "public" community.
SWR2311P(config)#no snmp-server community public
4.10.6 Set SNMP view
[Syntax]
snmp-server
view
view
oid
type
no
snmp-server
view
view
[Parameter]
view
:
View name (maximum 32 characters)
oid
:
MIB object ID
type
:
Type
Command Reference | Maintenance and operation functions |