AMP ADJUSTMENT
/ アンプ部調整
0.1mV ~ 10.0mV
(DC)
0.1mV ~ 10.0mV
(DC)
R113 (MAIN Lch)
R133 (MAIN Rch)
R187 (CENTER)
R106 (MAIN Lch)
R126 (MAIN Rch)
R183 (CENTER)
R146 (REAR Lch)
R164 (REAR Rch)
R151 (REAR Lch)
R169 (REAR Rch)
Cut off
カット
Confirmation of Idling Current of Main (1) P. C. B.
• Right after power is turned on, confirm that the voltage
across the terminals of R113 (Main Lch), R133 (Main
Rch), R187 (Center), R151 (Rear Lch), R169 (Rear
Rch) are between 0.1mV and 10.0mV.
• If it exceeds 10.0mV, open (cutoff) R106 (Main Lch),
R126 (Main Rch), R183 (Center), R146 (Rear Lch),
R164 (Rear Rch) and reconfirm the voltage.
• Confirm that the voltage is 0.2mV ~ 15.0mV after 60
minutes.
メイン
(1)
基板のアイドリング電流の確認
● 電源投入直後、R113(MAIN Lch)
、R133(MAIN Rch)
、
R187(CENTER)、R151(REAR Lch)、R169(REAR
Rch)の端子間電圧を測定し、0.1mVから10.0mVの間で
あることを確認してください。
● 電圧が10mVを超えている場合は、R106(MAIN Lch)、
R126(MAIN Rch)、R183(CENTER)、R146(REAR
Lch)、R164(REAR Rch)をカットし、電圧を再確認し
てください。
● 60分後、電圧が0.2mV〜15.0mVであることを確認して
ください。