17
RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS
No.9 AD DATA CHECK
The A/D conversion values of the main CPU which detects key scan, protection, etc. are displayed in % (100%: 5V).
All signal processing before this menu is executed will be held.
The keys on the main unit cannot be operated to detect the values of all keys in the K1/K2/K3/K4 and SI.
Operating the "PROGRAM" key and turning the rotary encoder (input selector on the main unit) will switch the submenu.
K1/K2/K3/K4: Panel key on main unit
See Table 1.
Turning the rotary encoder.
SI: Tuner signal level
Turning the rotary encoder.
DC: DC protection value
(normal value: 1-13)
Press the "PROGRAM "key.
PS: Power voltage protection value
Table 1
(normal value: 28-54)
AD Value
0
11
23
36
51
67
84
TIME/
LEVEL
TAPE/MD MON
/EXT. DECODER
7
A/B/C/D/E
TUNING
DOWN
8
TUNING
MODE
1
TUNING
UP
SET
MENU
–
MEMORY
2
+
INPUT MODE
EDIT
3
EFFECT
4
EON
PTY SEEK
MODE
FM/AM
5
PROGRAM
PTY SEEK
START
PROGRAM
RDS
MODE
6
K1
K2
K3
K4
1. If K1/K2/K3/K4 are more than
±
4% from the reference values, normal operation will not be executed.
2.If DC and PS are outside the normal values, the protection function will operate and power will turn off.
Cautions:
K1 K2 K3 K4
9 DVD/LD
AD CHECK
9 DVD/LD
33999999
9 DVD/LD
SI 0
9 DVD/LD
DC 7
9 DVD/LD
PS 40
Press the "PROGRAM "key.
Press the "PROGRAM "key.