5-45
PTT system
f.
Connect the positive battery lead to the
terminal “a”, and the negative battery lead
to the terminal “b”, and then check the PTT
relay for continuity.
g.
Disconnect the special service tool.
h.
Install the PTT relay.
i.
Connect the PTT relay coupler, battery
power source, ground lead, and PTT mo-
tor leads.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
Checking the PTT switch (on bottom
cowling)
1.
Measure:
• PTT switch input voltage
Out of specification
Check the wire har-
ness for continuity.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a.
Disconnect the PTT switch coupler “a”.
b.
Measure the input voltage between the
PTT switch coupler terminal and ground.
c.
Connect the PTT switch coupler.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
2.
Check:
• PTT switch continuity
Out of specification
Replace.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a.
Disconnect the PTT switch coupler.
b.
Check the PTT switch for continuity.
c.
Connect the PTT switch coupler.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
PTT relay continuity
“b”
“c”
“d”
“e”
Input voltage
12 V
Red (R)–Ground
G/
W
G
Lg
S
b
a
e
d
c
b
PTT switch continuity
Switch po-
sition
Terminal
“a”
“b”
“c”
UP
DN
R
a
Lg
R
S
b
c
b
a