5-28
Ignition unit and component
OL: Indicates an overload
c.
Connect the rectifier/regulator coupler.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
Ignition unit and component
Checking the ignition spark
1.
Check:
• Ignition spark
No spark
Check ignition system circuit.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a.
Disconnect the spark plug cap from the
spark plug.
b.
Connect the spark plug cap to the special
service tool “1”.
c.
Check the ignition spark using the YDIS
“Stationary test”.
Do not touch any of the connections of the
special service tool.
d.
Remove the special service tool, and then
connect the spark plug cap.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
Rectifier/regulator continuity
(testing diode mode)
Tester probe
Display value
(reference data)
(+)
(–)
a
b
OL
c
d
e
b
a
0.7–0.8 V
c
0.4–0.5 V
d
e
c
a
0.4–0.5 V
b
OL
d
e
d
a
0.4–0.5 V
b
OL
c
e
e
a
0.4–0.5 V
b
OL
c
d
Ignition checker (Spark gap tes-
ter) “1”
90890-06754
Spark checker “1”
YM-34487
OK