8-12
RECOMMENDED BATTERY SWITCH CAPACITY
Select a battery switch which covers the starting ampere given in the table.
If the battery cable connection points are increased, electric resistance will increase and perfor-
mance for starting will decrease.
If a lot of connections such as an automatic battery distribution system is used, the total electric
resistance of connections has to be 0.5 M
Ω
or less.
(reference)
BATTERY CHARGING CAPABILITY
The following chart shows the net capability to charge a battery.
In case of an isolator equipped model, the capability is the total of main and isolator lines.
* When the temperature of stator coil has risen, the battery charging capability tends to drop.
Applicable models
Starting current
(Amperes)
Carbureted 150 – 225 (2.6L)
195
F115A
260
F115B
285
HPDI 150–200 (2.6L)
216
F200–F250 (3.3L)
220
HPDI 200–300 (3.3L)
254
F150
250
F150, F165, F175, F200 (2.8L)
200
F350 (V8)
410
F200–F300 (4.2L)
250
Global model
US/CA model
Net capability
Note
F25D, FT25F, F20D
F25A, T25A/B
13 amps
F30B, F40F
F30A, F40A
13 amps
F70A, F40G
F70A
8.5 amps
F40H, F50H, FT50J, F60F, FT60G
F50B, T50B, F60B, T60B
9 amps
F75B, F75C, F80B, F90B, F100D
F75A, F90A
19 amps
F/FL115A
F/LF115A
16 amps
Global model
US/CA/ANZ model
Net capability
Note
F/FL115B
F/LF115B
27 amps
F/FL150A, F/FL150B
F/LF150A
21 amps
F/FL200B, F/FL200C, F/FL225B,
F225C, F/FL250A, F/FL250B,
F/FL250G
F/LF115B, F/LF200A, F/LF225A,
F/LF250A
27 amps
V6-3.3L (VCT)
F200D, F225D, F250C, F225G,
F250F, F275A
VF200LA, VF225LA, VF250LA
35 amps
VMAX (SHO)
F150C, F165A, F175A, F/FL200F,
F/FL200G
VF150A, F175A, F/LF200B,
F/LF200CA
42 amps
L4-2.8L
F/FL225F, F/FL250D, F/FL300B
F/LF225CA, F/LF250CA,
F/LF300CA
55 amps
V6-4.2L
F/FL350A
F/LF350CB
33 amps
V8-5.3L
Hr
A
Starting
current
(Amperes)
Содержание F150A
Страница 1: ...90894 62983 01 Worldwide Edition RIGGING GUIDE 2014 ...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 64: ...MEMO ...
Страница 126: ...3 38 REMOTE CONTROL ATTACHMENT KIT Part No 66T 48501 01 Global model E 40X US CA model ...
Страница 138: ...MEMO ...
Страница 150: ...4 12 6X4 MULTI FUNCTION TILLER HANDLE EXPLODED DIAGRAM FOR US EX F50B F60B F70A ...
Страница 154: ...4 16 6X4 MULTI FUNCTION TILLER HANDLE EXPLODED DIAGRAM FOR JAPAN EX F50H F60F F70A ...
Страница 164: ...MEMO ...
Страница 218: ...6 4 DIGITAL NETWORK GAUGE DIMENSIONS ROUND STYLE GAUGE DIMENSIONS Gasket thickness Template 0 5 0 02 mm in ...
Страница 221: ...6 7 OPTIONAL EQUIPMENT SPEED COOLANT PRESSURE SENSORS KIT Ref No Kit Part No Remarks 1 60V 8A4L2 02 F115A F115B 1 ...
Страница 266: ...MEMO ...
Страница 280: ...MEMO ...
Страница 285: ...8 5 100 mm 4 in L ...
Страница 293: ...MEMO ...
Страница 329: ...Produced in Japan Mar 2014 ABE E ...