5-8
GB
EMU00435*
ENGINE FAILS TO OPERATE
In the unlikely event of an ignition control
system malfunction, the engine speed
may become erratic or the engine may
stop.
In such a case, follow the procedure
below.
1)
Remove the electric cover
1
.
2)
Disconnect the connection of the yel-
low cord
2
(emergency circuit) to
return to the nearest port.
w
When the connection is disconnected, the
idling and low speeds are slightly higher
than normal. Use care when starting off
or stopping.
c
C
Follow this procedure only in an emer-
gency and just long enough to return to
port for repairs.
F1025A
q
w
F1046
67F-9-75 (GB•F•ES)-5 4/19/01 10:02 AM Page 22