19
Optional Accessories (sold separately)
Troubleshootin
g
If any specific problem should persist, please contact your Yamaha dealer.
Speaker
Cover
U-bracket
Wheels
DZR315(-D)
SPCVR-DZR315
—
—
DZR15(-D)
SPCVR-DZR15
UB-DZR15H, UB-DZR15V
—
DZR12(-D)
SPCVR-DZR12
UB-DZR12H, UB-DZR12V
—
DZR10(-D)
SPCVR-DZR10
UB-DZR10H, UB-DZR10V
—
DXS18XLF(-D)
SPCVR-DXS18X
—
SPW-1
DXS15XLF(-D)
SPCVR-DXS15X
—
SPW-1
Symptom
Possible causes
Possible solution
Power does not come on.
Time between turning the power on/off is too
short.
Wait about 20 seconds after turning the
power off before turning it back on again.
No sound.
Routing is not appropriate.
On the HOME screen, if there is a signal in the
Input Meter but no signal in the SP Output
Meter, check if the signal is routed to SP OUT
under ROUTER in the settings.
Level is low in DSP.
Check the INPUT level under ROUTER in the
settings, and raise it if it is too low.
No sound, or
intermittent sound.
Too many Dante devices in the daisy chain
for the current latency settings.
With the default setting (1 msec), a single
daisy chain can have up to 10 units. When
connecting more than 10 units, use an L2
switch (that supports Gigabit Ethernet) to cre-
ate branches in the network.
Volume becomes low sud-
denly.
Protection function is active because the
amp is too hot, triggering the limiter.
In such cases, THERMAL is displayed on the
HOME screen. To prevent the speaker from
getting hotter, improve the ventilation around
the rear panel and shield the panel from
direct sunlight.
Sound is interrupted sud-
denly.
Protection function is active because the
amp became hotter, triggering the mute
function.
In such cases, MUTED is displayed on the
HOME screen and at the same time the
[POWER] indicator flashes. To prevent the
speaker from getting hotter, improve the venti-
lation around the rear panel and shield the
panel from direct sunlight.
The speaker units are damaged.
If there is no sound even though MUTED is
not displayed on the HOME screen and there
is a signal in the SP Output Meter, the speaker
units might be damaged. Please contact your
Yamaha dealer.
Display goes off after a few
moments.
The protection function for the display is
active.
Press either the main knob or the [
]
(back) key to return to the normal display.
Dante model
Dante model
Содержание DZR315W