Assigning GPI Inputs
215
DME32—Owner’s Manual
You must compile and transfer the configuration to the DME32 for the GPI IN settings
to take effect. See “How to Build & Edit Configurations” on page 44 for more informa-
tion.
The GPI IN parameters are explained in the following table.
GPI settings are stored in configurations.
Scene & Configuration Recall
This connection diagram shows how a normally open switch can be
used to recall scenes and configurations. The assigned scene or config-
uration is recalled when the button is pressed (i.e., IN goes high).
Section
Parameter
Range
Description
GPI Select
UNIT
1–4
Selects a DME32
GPI CH
1–16
Selects a GPI input
Scene Change Scene Select
1–99
Assigns a scene to the selected GPI input
Parameter
UNIT
1–4
Selects the DME32 containing the parameter
to be assigned
COMPONENT
1
1. Components in the current configuration can be selected.
Selects the component whose parameter is
to be assigned
PARAMETER
2
2. Depends on the component selected.
Selects the parameter to be assigned
Configuration
Change
Configuration
Select
A, B
Assigns a configuration to the selected GPI
input
Emergency
Assigns the selected GPI input for use with
Emergency mode
Terminal Usage
(for use with Parameters only)
Normal
Reverse
Low-to-high
High-to-low
IN
GPI connection
+V