SELECTED CHANNEL section
10
Reference Manual
◆
EQ graph field
This field graphically indicates the approximate response of the EQ. Press this field to open
the HPF/EQ 1ch window, in which you can set the attenuator, HPF, and EQ.
◆
DYNAMICS1/DYNAMICS2 field
This field enables you to set the Dynamics 1/2 parameters.
1
2
3
4
1
OVER indicator
Warns you when the signal is clipping.
2
Level meter
Displays the output signal level (green) and the amount of gain reduction (orange)
when the Dynamics is on. The current threshold setting is shown as a white vertical line.
3
Threshold
Specifies the threshold.
4
Parameters
Indicate the values of parameters that vary depending on the currently-selected
dynamics type.
Press this field to open the DYNAMICS 1/DYNAMICS 2 1ch window, in which you can
make detailed parameter settings.
◆
INSERT field
This field enables you to make insert settings.
1
1
Popup button
Press this button to open the INSERT/DIRECT OUT
2
1ch window.
2
ON button
3
4
Switches the insert on or off.
3
RACK EDIT button
Appears if an effect or Premium Rack is inserted. Press this button to display the edit
screen for the inserted rack.
4
IN indicator
Appears if a port has been assigned to the insert-in patch. It lights when the signal is
sent to the insert-in.
◆
DIRECT OUT field
This field enables you to make Direct Out settings.
1
Popup button
Press this button to open the INSERT/DIRECT OUT 1ch
window. The Direct Out level value will appear below the
1
2
button.
2
ON button
Switches the Direct Out on or off.
◆
RECALL SAFE field
This field enables you to make Recall Safe settings.
1
1
Popup button
3
Press this button to open the RECALL SAFE window.
2
ON button
2
Switches the Recall Safe status on or off.
3
PARTIAL indicator
Lights only if some of the channel parameters are set to Recall Safe.
USO
RESTRITO
Содержание CL5