![Yamaha CEmarking RCX221 Скачать руководство пользователя страница 459](http://html2.mh-extra.com/html/yamaha/cemarking-rcx221/cemarking-rcx221_user-manual_3060670459.webp)
9-53
Chapter
9
TROUBLESHOOTING
1.2
RPB Error Messages
When a hardware error or a software error occurs in the RPB, the following messages are
highlighted (shown with reversed background) on the guideline of the lowest line of the
screen.
RPB TRAP!!
Contents
: Undefined operation code was executed.
Cause
: A hardware error occurred.
Action
: Replace the RPB.
RPB Receive Error!! (Data Register Full)
Contents
: Data receive register is full.
Cause
: A hardware error occurred.
Action
: Replace the RPB.
RPB Receive Error!! (Over Run Error)
Contents
: An overrun occurred while receiving data.
Cause
: a. Malfunction occurred due to noise.
b. The cable is broken or disconnected.
c. The connector is not making contact.
Action
: 1. Separate equipment away from noise source.
2. Replace the RPB cable.
3. Replace the RPB.
RPB Receive Error!! (Parity Error)
Contents
: Parity error occurred during communication.
Cause
: a. Malfunction occurred due to noise.
b. The cable is broken or disconnected.
c. The connector is not making contact.
Action
: 1. Separate equipment away from noise source.
2. Replace the RPB cable.
RPB Receive Error!! (Framing Error)
Contents
: Framing error occurred during communication.
Cause
: Malfunction occurred due to noise.
Action
: Separate equipment away from noise source.
RPB Receive Error!! (Buffer Overflow)
Contents
: Remaining area in receive buffer fell below 1% during
communications.
Cause
: a. Large amount of data was sent from the controller.
b. Communication control error.
Action
: 1. Replace the RPB.
2. Replace the controller.
1. Error Messages
Содержание CEmarking RCX221
Страница 2: ......
Страница 6: ...4 MEMO...
Страница 16: ......
Страница 30: ......
Страница 38: ......
Страница 62: ...3 24 MEMO...
Страница 68: ......
Страница 228: ...4 160 Chapter 4 OPERATION 12 SYSTEM mode 5 Repeat the above steps 3 and 4 if necessary 6 Press to quit the edit mode...
Страница 342: ......
Страница 366: ...5 24 MEMO...
Страница 368: ......
Страница 384: ......
Страница 396: ......
Страница 404: ...8 8 MEMO...
Страница 406: ......
Страница 467: ...MEMO...