![Yamaha CEmarking RCX221 Скачать руководство пользователя страница 263](http://html2.mh-extra.com/html/yamaha/cemarking-rcx221/cemarking-rcx221_user-manual_3060670263.webp)
4-195
Chapter
4
OPERA
TION
12. "SYSTEM" mode
12.1.4.3 Setting the network parameters
When using Ethernet, you set five parameters including the parameter to enable or disable
the Ethernet board.
c
CAUTION
When making the Ethernet settings to use TELNET, you will need to set any
other parameters than those shown below. For more details, see the Ethernet
manual.
Parameter
Meaning
1
Board condition
Enables or disables the Ethernet board. When set to
"VALID" the Ethernet can be used. When set to
"INVALID" Ethernet cannot be used.
2
IP address
Sets the IP address.
3
Subnet mask
Sets the subnet mask.
4
Gateway
Sets the gateway.
5
Communication
mode
Sets the communication mode (online/offline).
Online commands can be run only in the online mode.
n
NOTE
• The communication mode parameter is applicable to a controller of Ver.
9.27 onwards.
• The communication mode parameter can also be changed by the
ONLINE or OFFLINE statement of the robot language.
[Procedure]
■
Network setting (1)
SYSTEM
>PARAM>OP.BRD V9.00
1.E_Net
VALID
2.
3.
4.
SELECT
1) In "SYSTEM>PARAM>OP. BRD" mode, select "E_Net" with the cursor keys and press
(SELECT).
Содержание CEmarking RCX221
Страница 2: ......
Страница 6: ...4 MEMO...
Страница 16: ......
Страница 30: ......
Страница 38: ......
Страница 62: ...3 24 MEMO...
Страница 68: ......
Страница 228: ...4 160 Chapter 4 OPERATION 12 SYSTEM mode 5 Repeat the above steps 3 and 4 if necessary 6 Press to quit the edit mode...
Страница 342: ......
Страница 366: ...5 24 MEMO...
Страница 368: ......
Страница 384: ......
Страница 396: ......
Страница 404: ...8 8 MEMO...
Страница 406: ......
Страница 467: ...MEMO...