4
1
2
3
5
6
4-8
Chapter 4 EMC COUNTERMEASURE
4.1.2 RCX221/RCX222
4.1.2.1 Configuration
c
CAUTION
As shown in the following fi gure, the ferrite cores and noise fi lter on the
controller side should be placed as close to the controller body as possible.
The ferrite cores on the robot side should be placed as close to the robot
body as possible.
Power supply
(200 to 230V)
Ground
L
N
L1
N1
ROB I/O
XY
MOTOR
XM
YM
OP.DIO
NETWORK
COM
RPB
SAFETY
RGEN
Robot series
Single-axis
Cartesian
P&P
I/O circuit
network
RPB-E
RS-232C
External safety circuit
Regenerative unit
RCX221/RCX222
: Noise filter
NF2020A-UP : TDK-Lambda Corporation
: Ferrite core
ZCAT3035-1330 : TDK
: Ferrite core
1 turn
: Ferrite core
2 turn
Meaning of symbols
: Ferrite core
ZCAT2132-1130 : TDK
: Ferrite core
ZCAT2032-0930 : TDK
4.1 EMC countermeasure examples
Содержание CEmarking RCX221