4
1
2
3
5
6
3-14
Chapter 3 SYSTEM OVERVIEW
3.4.3.1 SERVICE mode level
The SERVICE mode level can be selected to enable or disable the Hold-to-Run function
and to permit or prohibit the operation in AUTO mode.
The Hold-to-Run function allows the robot to move (including program execution) only
during the time that the RPB-E operation key is kept pressed.
Setting
Description
Hold-to-Run function
AUTO mode operation
Level 0
Disabled
Permitted
Level 1
Enabled
Permitted
Level 2
Disabled
Prohibited
*
Level 3
Enabled
Prohibited
* Default setting
3.4.3.2 Limitations on operating speed during SERVICE mode
The maximum robot operating speed can be specified.
Setting
Description
*
< 3%
Robot operating speed is limited to below 3% of maximum
speed.
< 100%
Robot operating speed is not limited.
*Default setting
3.4.3.3 Operation device control during SERVICE mode
The operation device can be specified.
Setting
Description
*
RPB
Only RPB-E operation is enabled.
RPB/DI
RPB-E and dedicated input are enabled.
RPB/COM
RPB-E and online commands are enabled.
ALL
RPB-E, dedicated input, and online command operation
device are enabled.
*Default setting
c
CAUTION
Dedicated input is SI when a serial board is connected.
3.4 SERVICE mode
Содержание CEmarking RCX221
Страница 2: ......
Страница 4: ...MEMO 2 Introduction ...
Страница 8: ...MEMO iv General contents ...
Страница 10: ......
Страница 22: ......
Страница 26: ...MEMO 2 4 Chapter 2 CE MARKING ...
Страница 28: ......
Страница 44: ......
Страница 56: ...4 12 Chapter 4 EMC COUNTERMEASURE MEMO ...
Страница 58: ......
Страница 72: ...MEMO 5 14 Chapter 5 EXTERNAL SAFETY CIRCUIT EXAMPLES ...
Страница 74: ......
Страница 91: ...MEMO ...