En
77
■
Equalizer
Adjusts the tone with an equalizer.
Selects the type of equalizer to be used.
Settings
• “PEQ” is available only when the YPAO has been performed (p.27).
■
Manual equalizer adjustment
1
Set “EQ Select” to “GEQ”.
2
Use the cursor keys (
q
/
w
) to select “Channel” and the cursor keys (
e
/
r
) to
select the desired speaker channel.
3
Use the cursor keys (
q
/
w
) to select the desired band (frequency) and the
cursor keys (
e
/
r
) to adjust the gain.
Setting range
-6.0 dB to +6.0 dB
4
To exit from the menu, press SETUP.
■
Test Tone
Enables/disables the test tone output. Test tone output helps you to adjust the speaker
balance or equalizer while confirming its effect.
Settings
EQ Select
PEQ
Applies the parametric equalizer values obtained by the YPAO
measurement (p.27).
GEQ
Select this option when you want to adjust the equalizer manually.
For details, see “Manual equalizer adjustment”.
Off
Does not use the equalizer.
Equalizer
EQ Select
GEQ Edit
Channel
63Hz
160Hz
400Hz
1kHz
2.5kHz
6.3kHz
16kHz
GEQ
Front L
Back:RETURN
Off
Does not output test tones.
On
Outputs test tones automatically when you adjust the speaker balance
or equalizer.
00_RX-A550_om_U.book Page 77 Thursday, March 26, 2015 5:44 PM