TRBL
SHTG
9-7
6885J11
Troubleshooting
Refer
Symptom 2
Cause 1
Cause 2
Checking step
to
page
Troubleshooting the PTT unit
Symptom 1: PTT unit does not operate
PTT relay does
not operate
Short, open, or loose
connection of the
wiring harness
Check the wiring har-
ness for continuity.
WD
—
PTT relay malfunction
Check the PTT relay.
7-64
—
Short, open, or loose
connection of the PTT
motor lead
Check the PTT motor
lead and ground circuit.
WD
PTT motor does
not operate
Oil pressure
does not
increase
—
PTT motor malfunction
Disassemble and
check the PTT motor.
7-42
—
Blown fuse (20A)
Check the fuse (20A).
7-64
—
Discharged battery
Check the battery.
3-19
—
Loose connection of
the battery terminal
Check the battery ter-
minal.
—
—
Manual valve opened
Check the manual
valve for open.
—
Manual valve
malfunction
Insufficient PTT fluid
Add sufficient fluid.
3-15
7-40
—
PTT fluid leakage
Check the PTT unit for
leakage.
7-37
—
Clogged filter
Clogged fluid passage
Disassemble and
check the PTT unit.
7-35
7-50
—
WD: See the wiring diagram
6885J11_09 07.9.26 15:17 Page 8
Содержание 55DEHD
Страница 4: ......
Страница 24: ...GEN INFO 1 19 6885J11 General information MEMO ...
Страница 85: ...6885J11 9 8 7 6 5 4 3 2 1 4 16 MEMO ...
Страница 154: ...LOWR 6 25 6885J11 Lower unit Shimming T3 M3 M2 68860480 T2 T1 M1 P R F ...
Страница 260: ... MEMO ...
Страница 261: ... MEMO ...