50
Monitoring
01V96i—Reference Manual
3
SEL MODE
This parameter determines how the Input Channels will
be soloed when you press the [SOLO] button of each
Channel. There are two options.
• MIX SOLO
In Mix Solo mode, any number of channels can be soloed
simultaneously.
• LAST SOLO
In Last Solo mode, only one channel can be soloed at a
time by pressing the [SOLO] button. The Solo function
that was previously enabled for channels is automatically
cancelled.
4
LISTEN
This parameter determines the source of the Input Chan-
nel Solo signal: Pre Fader or Post Pan. When Pre Fader is
selected, turning on the PAN button below the Pre Fader
option will solo the channel with the pan position speci-
fied by the Pan setting even if the source precedes the
fader. This parameter is effective only in Recording Solo
mode.
5
SOLO TRIM
This parameter enables you to trim the level of the Solo
signal in the range of –96 dB to +12 dB.
6
FADER/SOLO RELEASE
If this check box is checked, you can unsolo the channels
by raising the channel faders that were at the level of –
when the Solo function was turned on. If the faders were
set to higher than –
, the channels cannot be soloed. This
setting is not effective in Mixdown Solo mode and for
Output Channels.
7
SOLO SAFE CHANNEL
For Mixdown Solo mode, Input Channels can be config-
ured individually so that they are not muted when other
Input Channels are soloed (Solo Safe function). Signals
from Input Channels with the SOLO SAFE CHANNEL
button turned on are always fed to the Stereo bus, regard-
less of the channels’ Solo function status. You can clear all
Solo Safe settings by turning on the ALL CLEAR button.
8
MONITOR TRIM
This parameter enables you to trim the level of the mon-
itoring signal in the range of –96 dB to +12 dB.
9
MONO
This button switches the Monitor signal into mono.
Using the Monitor
1.
Connect a monitoring system to the MONI-
TOR OUT connectors.
To monitor the signal via headphones, connect head-
phones to the PHONES jack.
2.
Press the Monitor Source selector in the
MONITOR section to select the monitoring
signal source.
To monitor the 01V96i’s internal signals, turn off the
selector (the button should be raised). To monitor the sig-
nals at the 2TR IN connectors, turn on the selector (the
button should be pushed in).
3.
Adjust the monitoring level using the MONI-
TOR [MONITOR LEVEL] control while playing
the sound sources.
To adjust the level of the monitoring signal via head-
phones, turn the [PHONES LEVEL] control.
Note:
When you check the FADER/SOLO RELEASE check
box, the Solo setting is temporarily cancelled.
Tip:
For example, if you set the internal effects processor’s
return signal to Solo Safe, you can monitor the soloed “pro-
cessed (or wet)” signals.
PHONES
MONITOR
OUT
MONITOR
2TR IN
LEVEL
PHONES
LEVEL
0
10
0
10