Battery-BDI Reset Percent
When a battery has a high BDI percentage, its float
voltage at KSI On can sometimes cause false resets.
The BDI Reset Percent parameter addresses this
problem by allowing the user to define a BDI
Percentage value above which the BDI Percentage
variable will not reset.
Undervoltage Cutback Range
Severe Undervoltage = Undervoltage point –
Undervoltage Cutback Range or Brownout voltage
(15V) whichever is higher. This parameter sets the
voltage range between the Undervoltage and Severe
Undervoltage points. A Severe Undervoltage fault will
be set if the capacitor voltage falls below either the
Severe Undervoltage point (drive current limit set to 0)
or the Brownout voltage (bridge disabled, motor
current set to 0).
User Undervoltage
Undervoltage = Either Min Voltage controller voltage
(16.8V) or User Undervoltage × Nominal Voltage,
whichever is higher. The User Undervoltage parameter
can be used to adjust the undervoltage threshold,
which is the voltage at which the controller will cut
back drive current to prevent damage to the electrical
system. The undervoltage threshold can never be
lowered below the controller’s power base minimum
voltage rating.
Total Maintenance Enable
This parameter will activate BDI maintenance reminder
for truck to be serviced after certain amount of total
hours have been accumulated in the hour meters.
Traction Maintenance Enable
This parameter will activate BDI maintenance reminder
for truck to be serviced after certain amount of Traction
hours have been accumulated in the hour meters.
Pump Maintenance Enable
This parameter will activate BDI maintenance reminder
for truck to be serviced after certain amount of Pump
hours have been accumulated in the hour meters.
Maintenance Interval
This parameter will sets the time interval at which the
truck shall receive regular maintenance.
Reset Total Maintenance
This parameter will set back to zero the maintenance
interval counter.
Reset Traction Maintenance
This parameter will set back to zero the maintenance
interval counter.
Reset Pump Maintenance
This parameter will set back to zero the maintenance
interval counter.
ELECTRICAL SYSTEM
General Maintenance and Diagnostic Data
Check the Service Manual section in Yale Axcess Online for possible updates and check pertinent Bulletins
Confidential/Proprietary - Do Not Copy or Duplicate
9030-03-11
Содержание MPB045VG
Страница 1: ...Maintenance CONTROLLER DIAGNOSTICS MPB045VG A245 PART NO 550095689 9000 YRM 1671 ...
Страница 4: ......
Страница 6: ......
Страница 10: ...9030 4 ...
Страница 24: ...NOTES 9030 03 14 ...
Страница 83: ......
Страница 84: ...9000 YRM 1671 10 19 9 15 1 15 12 14 10 14 4 14 ...