![Yale MPB040-E Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/yale/mpb040-e/mpb040-e_manual_3124464077.webp)
Battery Pack Troubleshooting
WARNING
Disconnect the charger from the AC power source
before proceeding.
Always wear protective gear including eye protec-
tion and suitable gloves when servicing battery
packs.
NOTE:
For general information about battery mainte-
nance and procedures, refer to
Industrial Battery
2240YRM0001.
1.
Measure the specific gravity (SG) level for each
battery cell (after a charging cycle).
After a charging cycle, the SG measurement for each
cell should be 1.265 or greater.
From cell to cell within one battery: The SG measure-
ments should not vary more than 0.020. If variance is
greater than 0.020, it is recommended that the battery
be replaced with the same type of battery as the other
three batteries in that pack.
From battery to battery within one battery pack: The
SG measurements should not vary more than 0.050.
If one of the batteries has an SG reading 0.050 below
the other three batteries and the voltage is less than
6.3VDC after allowing the batteries to set four hours
without any load, it is recommended that the battery
with lowest SG be replaced with the same type of bat-
tery as the other 3 batteries in that pack.
WARNING
DO NOT overfill battery cells.
2.
Verify water level in each cell of each battery:
•
Before Charging: Only add minimal amount
of distilled water to cover top of plates if
needed.
•
After Charging: Add distilled water as nee-
ded to fill to the bottom of cell opening.
3.
Battery Replacement: Each battery manufacturer
has a specific "charge set-up" that will give your
truck the best battery life and drive time for your
truck. If the "charge set-up" is not correct, you can
damage the batteries and will not get the full per-
formance you expect. Make sure that the battery
charger is set to the proper charging mode for
your battery pack.
•
DO NOT mix manufacturers or battery
types in the power pack
•
It is not recommended to change out bat-
teries independently. All batteries should
be changed together when battery pack is
updated.
2200 YRM 1007
Battery Charger (Accusense
®
20A)
53
Содержание MPB040-E
Страница 4: ......
Страница 10: ...Hydraulic Pump 1900 YRM 1018 Figure 4 Hydraulic Unit 6 ...
Страница 19: ......
Страница 65: ...Figure 30 Switch Position Mode Chart 2200 YRM 1007 Battery Charger Accusense by DPI 41 ...
Страница 79: ......
Страница 80: ...2200 YRM 1007 10 16 8 16 1 14 9 13 12 12 7 11 ...
Страница 81: ...Maintenance LIFTING MECHANISM MPB040E B827 MPW045 E B802 MPW050 E C802 PART NO 524154897 4000 YRM 1008 ...
Страница 84: ......
Страница 93: ......
Страница 95: ...Maintenance DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO 524158039 0620 YRM 0294 ...
Страница 98: ......
Страница 128: ...NOTES 30 ...
Страница 129: ......
Страница 130: ...0620 YRM 0294 9 16 3 08 6 15 3 06 8 03 ...