E
11.2.2
Pole-changing hoist motors 12/2H..-MF 60Hz
60 Hz
Motor
*3
Power
Duration
factor
Switching/
hour
Nominal
current
Starting
current
Nominal
current
Starting
current
cos phi k
Main fuse CC / J
*2
208…230
V
360…400
V
208…230
V
360…400
V
[HP]
CDF [%]
[c/h]
I
N
[A]
I
K
[A]
I
N
[A]
I
K
[A]
[A]
12/2H33-MF
0.7/4.7
20/50
360/180
8.2/15.3
15.3/89.9
4.7/8.8
8.8/52.1
0.73/0.77
25
20
0.9/5.8
20/40
240/120
8.4/17.0
4.8/10.0
12/2H42-MF
0.9/5.8
20/50
360/180
10.2/17.8
17.6/102.0
5.9/10.3
10.2/59.3
0.74/0.78
25
20
1.2/7.2
20/40
240/120
11.0/22.0
6.5/13.0
12/2H62-MF
1.6/9.7
20/60
480/240
17.8/28.2
31.4/167.0
10.3/16.3
18.2/96.8
0.68/0.75
50
30
1.9/12.1
20/50
360/180
18.0/33.0
10.5/19.0
12/2H71-MF
*1
1.6/9.7
20/60
480/240
17.8/28.2
31.4/167.0
10.3/16.3
18.2/96.8
0.68/0.75
60
60
1.9/12.1
20/50
360/180
18.2/33.5
10.5/19.4
2.1/14.8
20/40
240/120
21.0/42.0
12.0/24.0
12/2H72-MF
*1
3.1/18.8
20/50
360/180
27.2/54.4
52.3/312.0
15.7/31.5
30.3/180.0
0.64/0.60
80
50
4/24.1
20/40
240/120
27.0/67.0
16.0/39.0
12/2H91-MF
*1
8/48.3
20/40
240/120
54.0/121.0
94.1/523.0
31.5/70.0
54.5/303.0
0.60/0.70
125
60
60 Hz
Motor
*3
Power
Duration
factor
Switching/
hour
Nominal
current
Starting
current
Nominal
current
Starting
current
cos phi k
Main fuse CC / J
*2
440…480
V
575…600
V
440…480
V
575…600
V
[HP]
CDF [%]
[c/h]
IN [A]
IK [A]
IN [A]
IK [A]
[A]
12/2H33-MF
0.7/4.7
20/50
360/180
3.9/7.3
7.3/43.0
3.1/5.8
5.8/34.4
0.73/0.77
15
15
0.9/5.8
20/40
240/120
4.0/8.3
3.2/6.6
12/2H42-MF
0.9/5.8
20/50
360/180
4.9/8.5
8.4/49.0
3.9/6.8
6.7/39.2
0.74/0.78
15
15
1.2/7.2
20/40
240/120
5.4/10.0
4.3/8.2
12/2H62-MF
1.6/9.7
20/60
480/240
8.5/13.5
15.0/80.0
6.8/10.8
12.0/64.0
0.68/0.75
25
20
1.9/12.1
20/50
360/180
8.7/16.0
7.0/12.8
12/2H71-MF
*1
1.6/9.7
20/60
480/240
8.5/13.5
15.0/80.0
6.8/10.8
12.0/64.0
0.68/0.75
30
25
1.9/12.1
20/50
360/180
8.7/16.0
7.0/12.8
2.1/14.8
20/40
240/120
10.0/20.0
8.0/16.0
12/2H72-MF
*1
3.1/18.8
20/50
360/180
13.0/26.0
25.0/149.0
10.4/20.8
20.0/119.0
0.64/0.60
50
30
4/24.1
20/40
240/120
13.0/32.0
10.0/26.0
12/2H91-MF
*1
8/48.3
20/40
240/120
26.0/58.0
45.0/250.0
21.0/47.0
36.0/200.0
0.60/0.70
60
50
Tab. 43
Motor currents at other voltages:
Formula
𝐼
𝑥 𝑉
= 𝐼
400 𝑉
∗
400 𝑉
𝑥 𝑉
*1 Operation only with special starting circuit via 12-pole winding.
*2 The 2-pole starting current for main hoist and the rated current for the travel motor were taken into
consideration when selecting the main fuse.
*3 The motors are designed for rated voltage ranges. In accordance with EN 60034 a voltage tolerance of
±5 % and a frequency tolerance of ±2 % apply on top of the rated voltage ranges. The maximum current
occurring in the rated voltage range is given.