INSTALLATION 

3.1 

Installing the KEMET Flame Sensing Evaluation Tool Software 

From the  software  pack  available  to  downloa

here

,  select  the 

setup.exe

  file  that  has this 

icon.  This will start the installation process.   

 

Figure 2 

– Installer Screen 

Follow the on screen instructions and enter the information required.  

As  part  of  the  installation  process  a  check  will  take  place  to  see  if  .NET  Framework  4.5  is 
present. If not, it can be installed as part of the setup routine or alternatively the setup routine 
can be cancelled and the .NET framework 4.5 

can be downloaded from Microsoft’s website. 

The framework can take a while to install but the software requires it. 

3.2 

Connecting the TO Flame Sensing Evaluation Kit 

Connect the power supply provided to the KEMET Flame Detection Demonstrator Kit. Then 
connect the USB cable to the kit and Windows PC. You may see a message suggesting you 
are required to install a device driver. You can either. Follow the on-screen instructions and 
download a driver from Windows Update. 

Your kit is now installed and ready to use. 

SOFTWARE USER GUIDE 

The KEMET Flame Sensing Evaluation Tool software runs on Microsoft Windows PCs and 
communicates with the Flame Detection Demonstrator Kit USEQFCK4000000, which enables 
easy testing of KEMET QFC TO packaged flame sensors. The software provides an interface 
to the analog circuits and A-D (Analog to Digital) converter, which are provided by the Silicon 
Labs C8051F350. Additional signal processing and analysis algorithms to filter and analyze 
sensor  output  for  flame  detection  are  provided.  These  include  a  simple  flame  detection 
algorithm using Fast Fourier Transform of sensor signals and threshold level based analysis 
of 10 Hz components of these signals. 

Содержание KEMET USEQFCK4000000

Страница 1: ...t but does not purport to be all inclusive and must be used only as a guide KEMET Electronics Corporation KEMET Tower One East Broward Boulevard Fort Lauderdale FL 33301 USA 954 766 2800 www kemet com...

Страница 2: ...INTRODUCTION 3 2 GETTING STARTED 3 2 1 Kit Contents 3 2 2 Minimum System Requirements 3 3 INSTALLATION 4 3 1 Installing the KEMET Flame Sensing Evaluation Tool Software 4 3 2 Connecting the TO Flame...

Страница 3: ...sed algorithm and to capture measured data to a PC The kit is based on the Silicon Labs C8051F350 microcontroller with a high precision A D converter and programmable gain amplifier It is capable of s...

Страница 4: ...while to install but the software requires it 3 2 Connecting the TO Flame Sensing Evaluation Kit Connect the power supply provided to the KEMET Flame Detection Demonstrator Kit Then connect the USB ca...

Страница 5: ...com 5 4 1 Starting the Software To start the software select the following from the windows start button in your task bar This will open up the KEMET sensor data capture main screen as shown below Fi...

Страница 6: ...re 4 Flame Detection Demonstrator Kit Connection This will open up a further dialog box asking you to select on which com port the data capture board is using as shown in Figure Figure 5 Com Port Sele...

Страница 7: ...how the Flame Detection Demonstrator Kit firmware version Sensor signal will be visible on the signal viewers on the right If the program fails to make a connection to the data capture board an error...

Страница 8: ...channel Gain of 1 means no additional amplification is applied to the sensor signal thus x1 The remaining settings of X give multiples of the signal levels obtained at gain of 1 For example gain selec...

Страница 9: ...cy domain representation of the signal useful for looking at dominant frequencies in signals relative magnitude for example comparison of flame flicker frequency and human motion frequency o 10 Hz Sig...

Страница 10: ...tion However detection time is increased to around 15 seconds with the highest setting 10 Hz Response This is the final result from the preprocessing for each channel The relative levels from the chan...

Страница 11: ...n front of the sensors Expected outcome a Signal viewer for Ch1 flame filter i generally a higher response is shown on Ch1 for flame test at the moment of starting the flame than on Ch2 for hand wavin...

Отзывы: