Yaesu VL-1000 Скачать руководство пользователя страница 7

Page 6

VL-1000 Operating Manual

4.  LOW Switch

This switch selects the RF output power.

When in the LOW position, the RF output
power will be reduced to (approximately) 500
watts PEP, and  “

LOW

” will appear on the dis-

play.
Note: This switch should be set to the LOW
position when operating from a 100 ~ 117 VAC
power source.

5.  INPUT Switch

Press this switch to toggle between the ex-

citers connected to the INPUT 1 and INPUT 2
connectors on the rear panel.  The indicator

INPUT 1

” or “

INPUT 2

” will appear on the dis-

play to indicate which exciter is in use.

6.  ATT Switch

This switch activates a 3 dB input RF power

attenuator, to reduce excessive input power
from the exciter.  It should be on if exciter out-
put exceeds 100 watts PEP, as is the case
when using the FT-1000/D.  The “

ATT

” indica-

tor will appear on the display when this switch
is on.

Front Panel Controls and Switches

1.  POWER Switch

This switch turns the VL-1000 on and off.

When the amplifier is turned off, the INPUT 1
jack is connected directly to the ANT 1 jack.  If
using a Yaesu transceiver with a B

AND

 D

ATA

cable, the VL-1000 AC power will be  remotely
controlled by the 

transceiver’s power switch

when the REMOTE switch on the rear panel
of the VL-1000 is set to ON.

2.  OPERATE Switch

Pressing this switch activates the power am-

plifier section of the VL-1000.  When the power
amplifier is activated, “

OPERATE

” will appear

on the display.  Press this switch again to turn
off the power amplifier section.

3.  DIM Switch

This switch selects the brightness level of

the LCD display. In low-light situations, acti-
vating the Dimmer may reduce excess bright-
ness in the display.  For normal room lighting,
however, the Dimmer should be set to OFF
for best visibility.

Содержание VL-1000

Страница 1: ...0703 U S A YAESU EUROPE B V Snipweg 3 1118DN Schiphol The Netherlands YAESU UK LTD Unit 12 Sun Valley Business Park Winnall Trading Estate Winchester Hampshire SO23 0LB U K YAESU GERMANY GmbH Am Kronb...

Страница 2: ...ion of antennas for different bands Extensive self test system monitoring and protection circuits are provided with status and tuning information being displayed on a huge Liquid Crystal Display panel...

Страница 3: ...nges However the AC power cable plug configu ration will be somewhat different depending on the country in which you purchased your amplifier In some countries the VP 1000 is shipped with the standard...

Страница 4: ...for the correspond ing exciter as the T R control signal will be made via the BAND DATA cable ceiver a BAND DATA cable may be con nected which provides automatic band change and T R control thus elimi...

Страница 5: ...1 ANT 4 The antenna to be used on a particular band will be memo rized once you make the selection manually via the front panel ANT switch See the Op eration section of this manual for more de tails...

Страница 6: ...D F 12V INPUT G 12V INPUT BAND DATA 2 DC48V IN 13 5V A TX GND B GND C BAND DATA A D BAND DATA B E BAND DATA C F BAND DATA D G TX INH H F SET COMMON I F SET 1 J F SET 2 K NC L NC M NC N GND 48V INPUT A...

Страница 7: ...FT 1000 D The ATT indica tor will appear on the display when this switch is on Front Panel Controls and Switches 1 POWER Switch This switch turns the VL 1000 on and off When the amplifier is turned o...

Страница 8: ...ust the LCD contrast 15 LCD Display The upper half of the display consists a 320 x 60 dot matrix display showing operating sta tus of the VL 1000 including the Graphical SWR meter The lower half conta...

Страница 9: ...of heavy braided cable All other station equip ment should be grounded to the same ground system 1 ANTENNA Jacks Connect these type M SO 239 jacks to your antennas using large RG 213 or larger 50 imp...

Страница 10: ...voltage for the power amplifier of the VL 1000 Rear Panel Connectors and Switch Operating Advice For most operating situations the REMOTE switch on the rear panel of the VL 1000 should be set to the...

Страница 11: ...the frequency of the input signal and the amplifier will then set it self to the matching band 4 When the correct band appears on the VL 1000 display release the exciter s PTT switch so as to return...

Страница 12: ...he following display will be shown Operation Metering An extensive array of metering selections are available to the owner of the VL 1000 Pressing the DISPLAY SELECT switch allows you to choose from a...

Страница 13: ...power ALC Alignment When this amplifier is used with Yaesu transceivers such as the FT 1000MP FT 990 or FT 920 the ALC system normally will not require alignment However if it appears that full power...

Страница 14: ...tent r During antenna tuning a special Antenna Tuning Meter display will be observed show ing the progress of the SWR reduction as well as showing a depiction of the relative positions of the two Vari...

Страница 15: ...e AVG power meter on the VL 1000 does not exceed 250 watts when transmitting a carrier On voice peaks adjust the MIC GAIN control on the trans ceiver so that the PEAK power meter on the VL 1000 does n...

Страница 16: ...ecommended drive level from the exciter transceiver has been exceeded Reduce the drive level or set the ATT switch to the ON po sition r 1005 PROTECTION CIRCUIT DETECTS EXCESSIVE PA DC VOLTAGE The rec...

Страница 17: ...Meter Amateur Bands less than 60 dB 6 Meter Amateur Band Third order IMD less than 30 dB 1000 W PEP Typical Input Output Impedance 50 unbalanced Automatic Antenna Tuner Section Impedance Matching Ran...

Страница 18: ...Copyright 1997 Yaesu Musen Co Ltd All rights reserved No portion of this manual may be reproduced without the permission of Yaesu Musen Co Ltd Printed in Japan E08971000 9708B 0K...

Отзывы: