Yaesu VL-1000 Скачать руководство пользователя страница 15

Page 14

VL-1000 Operating Manual

Operation

Linear Amplifier Operation

Although continuous full exciter power is re-

quired for accurate SWR measurement and
antenna matching, this will cause overheating
if transmitting for an extended period when
OPERATE switch is depressed (that is, when
the power amplifier section is on).  So once
the antenna has been matched the first time,
reduce the setting of the exciter’s D

RIVE

 or R

F

P

WR

 control if you contemplate operation us-

ing a continuous-carrier operating mode (see
the guidelines below).

For SSB and CW operation, make sure to

adjust the M

IC

 G

AIN

 and/or D

RIVE

 control on the

transceiver for proper ALC indication on the
transceiver ALC meter, as described in the
transceiver manual.  Generally, for SSB, the
ALC meter indication should not deflect be-
yond a certain ALC limit (the “ALC” zone on
the transceiver’s meter) on voice peaks; on
CW, the ALC indication should be just enough
to cause slight meter deflection.  Higher ALC
levels may produce distortion or key clicks,
without producing any additional power output.

For FM, SSTV, RTTY, AMTOR or packet,

press the LOW switch to select the LOW power
condition to prevent the overheating during
continuous operation for extended periods.

For AM operation, adjust the D

RIVE

 or R

F

P

WR

 control on the transceiver so that the AVG

power meter on the VL-1000 does not exceed
250 watts when transmitting a carrier.  On voice
peaks, adjust the M

IC

 G

AIN

 control on the trans-

ceiver so that the PEAK power meter on the
VL-1000 does not exceed 1000 watts.

     Operating Precautions

Summarized below are some precautions to adhere to in order to ensure long life and trouble-
free operation with the VL-1000.

r

Do not transmit, after changing bands, until “

COMPLETE

” appears on the display.

r

Do not transmit when turning the POWER switch or the ATT switch on or off.

r

When changing bands, always make certain that the VL-1000 is set for the same band as
the transceiver before transmitting, and that the proper antenna is connected.  Remem-
ber that ANT 1 is automatically selected when the VL-1000 is switched off.

r

Reduce the drive power or shorten transmissions if Warning Message #1001 appears on
the display (see next page).

Beeper on/off

When you press a switch, the beeper pro-

vides useful audible feedback to confirm that
the switch was successfully activated.

If you want to turn the beeper off, first turn

the VL-1000 off, then 

press and hold in the

DISPLAY 1 and DISPLAY 2 switches while you
turn the VL-1000 on. To turn the beeper back
on again, repeat this switch-on procedure.

Resetting the CPU

The VL-1000 can be reset so as to clear all

settings, display memories, and antenna tuner
data; these will be reset to their factory de-
faults.

To reset the microprocessor, 

press and hold

in the OPERATE and DIM switches while you
turn the VL-1000 on.

Содержание VL-1000

Страница 1: ...0703 U S A YAESU EUROPE B V Snipweg 3 1118DN Schiphol The Netherlands YAESU UK LTD Unit 12 Sun Valley Business Park Winnall Trading Estate Winchester Hampshire SO23 0LB U K YAESU GERMANY GmbH Am Kronb...

Страница 2: ...ion of antennas for different bands Extensive self test system monitoring and protection circuits are provided with status and tuning information being displayed on a huge Liquid Crystal Display panel...

Страница 3: ...nges However the AC power cable plug configu ration will be somewhat different depending on the country in which you purchased your amplifier In some countries the VP 1000 is shipped with the standard...

Страница 4: ...for the correspond ing exciter as the T R control signal will be made via the BAND DATA cable ceiver a BAND DATA cable may be con nected which provides automatic band change and T R control thus elimi...

Страница 5: ...1 ANT 4 The antenna to be used on a particular band will be memo rized once you make the selection manually via the front panel ANT switch See the Op eration section of this manual for more de tails...

Страница 6: ...D F 12V INPUT G 12V INPUT BAND DATA 2 DC48V IN 13 5V A TX GND B GND C BAND DATA A D BAND DATA B E BAND DATA C F BAND DATA D G TX INH H F SET COMMON I F SET 1 J F SET 2 K NC L NC M NC N GND 48V INPUT A...

Страница 7: ...FT 1000 D The ATT indica tor will appear on the display when this switch is on Front Panel Controls and Switches 1 POWER Switch This switch turns the VL 1000 on and off When the amplifier is turned o...

Страница 8: ...ust the LCD contrast 15 LCD Display The upper half of the display consists a 320 x 60 dot matrix display showing operating sta tus of the VL 1000 including the Graphical SWR meter The lower half conta...

Страница 9: ...of heavy braided cable All other station equip ment should be grounded to the same ground system 1 ANTENNA Jacks Connect these type M SO 239 jacks to your antennas using large RG 213 or larger 50 imp...

Страница 10: ...voltage for the power amplifier of the VL 1000 Rear Panel Connectors and Switch Operating Advice For most operating situations the REMOTE switch on the rear panel of the VL 1000 should be set to the...

Страница 11: ...the frequency of the input signal and the amplifier will then set it self to the matching band 4 When the correct band appears on the VL 1000 display release the exciter s PTT switch so as to return...

Страница 12: ...he following display will be shown Operation Metering An extensive array of metering selections are available to the owner of the VL 1000 Pressing the DISPLAY SELECT switch allows you to choose from a...

Страница 13: ...power ALC Alignment When this amplifier is used with Yaesu transceivers such as the FT 1000MP FT 990 or FT 920 the ALC system normally will not require alignment However if it appears that full power...

Страница 14: ...tent r During antenna tuning a special Antenna Tuning Meter display will be observed show ing the progress of the SWR reduction as well as showing a depiction of the relative positions of the two Vari...

Страница 15: ...e AVG power meter on the VL 1000 does not exceed 250 watts when transmitting a carrier On voice peaks adjust the MIC GAIN control on the trans ceiver so that the PEAK power meter on the VL 1000 does n...

Страница 16: ...ecommended drive level from the exciter transceiver has been exceeded Reduce the drive level or set the ATT switch to the ON po sition r 1005 PROTECTION CIRCUIT DETECTS EXCESSIVE PA DC VOLTAGE The rec...

Страница 17: ...Meter Amateur Bands less than 60 dB 6 Meter Amateur Band Third order IMD less than 30 dB 1000 W PEP Typical Input Output Impedance 50 unbalanced Automatic Antenna Tuner Section Impedance Matching Ran...

Страница 18: ...Copyright 1997 Yaesu Musen Co Ltd All rights reserved No portion of this manual may be reproduced without the permission of Yaesu Musen Co Ltd Printed in Japan E08971000 9708B 0K...