Page 98
FT-950 O
PERATING
M
ANUAL
M
EMORY
S
CAN
VFO
AND
M
EMORY
S
CANNING
1. Set the transceiver up in the “Memory” mode by press-
ing the [
V/M
] button, if necessary.
A
DVICE
:
If you can not enter the “Memory” mode, check to see
if the transceiver is in VFO-B mode (the green [
VFO-
B
(
RX
)] Indicator/Switch is illuminated). If so, press
the [
VFO-A
(
RX
)] Indicator/Switch to return operation
to VFO-A. Now, press the [
V/M
] button to enter the
“Memory” mode.
2. Rotate the [
SQL
] knob so that the background noise is
just silenced.
3. Press and hold in the microphone’s [
UP
] or [
DWN
]
key for one second to start scanning in the specified
direction.
A
DVICE
:
If the scanner halts on an incoming signal, the deci-
mal point between the “MHz” and “kHz” digits of
the frequency display will blink.
If the incoming signal disappears, scanning will re-
sume in about five seconds.
4. To cancel scanning, press the microphone’s [
UP
] or
[
DWN
] key momentarily.
A
DVICE
:
During Memory Group operation, only the channels
within the current Memory Group will be scanned.
If the scan has paused on a signal, pressing the
microphone’s [
UP
] or [
DWN
] key will cause scanning
to resume instantly.
If you press the microphone’s
PTT
switch during scan-
ning, the scanner will halt at once. However, pressing
the
PTT
switch during scanning will not cause trans-
mission.
You may select the manner in which the scanner re-
sumes while it has paused on a signal, using Menu item
“
034 GEnE SCN RSM
034 GEnE SCN RSM
034 GEnE SCN RSM
034 GEnE SCN RSM
034 GEnE SCN RSM
”. During memory scanning,
the default “
5SEc
5SEc
5SEc
5SEc
5SEc
” setting will cause the scanner to
resume scanning after five seconds. However, you may
change this setting to resume only after the carrier has
dropped out, if you like. See page 111.
[SQL] Knob
[VFO-B(RX)] Button
Q
UICK
P
OINT
:
If you have no interest in scanning, and wish to prohibit
the microphone’s [
UP
]/[
DWN
] keys from initiating scan-
ning, you may disable scanning control from the micro-
phone using Menu item “
033 GENE MIC SCN
033 GENE MIC SCN
033 GENE MIC SCN
033 GENE MIC SCN
033 GENE MIC SCN
” (set it to
“
OFF
OFF
OFF
OFF
OFF
”).
[V/M] Button
[VFO-A(RX)] Button
Содержание FT-950
Страница 13: ...Page 11 FT 950 OPERATING MANUAL CONNECTION OF MICROPHONE AND HEADPHONE INSTALLATION AND INTERCONNECTIONS...
Страница 79: ...Page 77 FT 950 OPERATING MANUAL CW CONVENIENCE FEATURES NOTE...
Страница 105: ...Page 103 FT 950 OPERATING MANUAL Note...
Страница 121: ...Page 119 FT 950 OPERATING MANUAL MENU MODE...
Страница 130: ...Page 128 FT 950 OPERATING MANUAL NOTE...