44
FT-817
ND
Operating Manual
QMB C
HANNEL
QMB Channel Storage
1. Tune in the desired frequency and set the operating mode and bandwidth. If this is an
FM channel, set up any required CTCSS/DCS and repeater shift configurations.
2. Press and hold in the
key until a
double
“beep” is heard. The second beep provides
audible confirmation that the data has been stored into the QMB memory.
Pressing the
(
A
/
B
)
key momentarily while in Operating Function Row 3
[
STO
,
RCL
,
PMS
]
will also store a frequency into the QMB register.
QMB Channel Recall
1. Press the
key momentarily, then rotate the
knob, as needed, until Operating
Function Row 3 [
STO
,
RCL
,
PMS
] appears on the display.
2. Press the
(
RCL
) key momentarily to recall the QMB memory. “
QMB
” will appear
at the upper right corner on the LCD.
3. Press the
(
RCL
) key once more to return to the previous frequency (either a VFO
frequency or a Memory channel).
If you move the
knob or
knob while in the QMB mode, you can
change frequencies as if you were in a “VFO” mode. You also can change operat-
ing mode by pressing the
or
key. When this is done, the “
MTQMB
”
will appear in the display, where “
MT
” represents “Memory Tuning.” Press the
(
RCL
)
key once more to return to the originally-stored QMB frequency.
M
EMORY
O
PERATION
Содержание FT-817ND