● In order to facilitate cooling and maintenance, sufficient space must be left around the inverter.
● In order to achieve a good cooling effect, the inverter must be installed vertically and ensure smooth air circulation.
● If the installation is not secure, place a flat plate under the base of the inverter before installing. If installed on a
loose surface, the stress may cause damage to the main circuit parts, thus damaging the inverter;
● The installation wall should use non-combustible materials such as iron plates.
● When multiple inverters are installed in the same cabinet, pay attention to the spacing when installing them up and
down, and add a baffle plate in the middle.
● Be sure to correctly connect the inverter main circuit and control signal wires.
● Be sure to set the inverter parameters correctly.
Note: Power supply: Please pay attention to whether the voltage levels are consistent to avoid damage to the inverter.
The environment of the installation site will affect the service life of the inverter.
3.2 Main circuit terminal description
:
3.3 Control terminal description
:
Terminal symbol
Description
N
L
Power input terminal (220V inverter is single-phase 220V input)
U.V.W
Inverter output terminal (220V inverter is three-phase 220V output)
+ DB -
Braking resistor connection end optional (see page 31 for details on braking resistor
configuration)
FG
Frame Ground
Terminal symbol
Description
Factory setting
X1
Multi-function input 1
X2
Multi-function input 2
X3
Multi-function input 3
X4
Forward
X5
Reverse
COM
Common terminal of digital control
signal
AI1
Analog current frequency command
5V
Power supply for speed setting
12V
Power supply for speed setting