RESIN CARE
•
Wear proper protective equipment, avoid raw material contact and vapor inhalation.
•
Chemical-resistant gloves should be worn when you make contact with resin.
•
Resin should preferably be stored at temperatures between 10-32°C (50-89.6°F), localized heat
sources (i.e., drum or band heaters), oxidizing conditions, freezing conditions, direct sunlight,
ultraviolet radiation, inert gas blanketing.
•
Never pour the waste resin back to the bottle or down the sink, as it may pollute the remaining resin or
clog the drain.
•
You may pour resin waste into plastic bag and expose it to sunlight or UV light source to cure the resin. The
cured resin can then be discarded.
•
Avoid dripping resin on anything other than the platform or the resin tank, or the printer may malfunction.
•
Please ensure that the recommended operating conditions are adhered to. (Operating temperature
20-30°C (68-86°F) / humidity 40 ~ 60% RH; If a different operating temperature is printed on the label
on the resin bottle, please adhere to recommended conditions on the label.)
•
For the best printing quality, resin should be used up within 3 months after purchasing and within 1 month
of opening.
RESIN TANK CARE
•
The resin tank is consumable. It should be replaced when the bottom is damaged or gets cloudy to ensure
the printing quality.
•
It is suggested to use isolated resin tank while different color resin is going to be used to ensure printing
quality.
PRINTING PROCESS
•
Keep the covers securely closed during printing.
•
The printing quality may be affected if resin temperature is changed due to opening the cover(s).
LED LIGHT
•
The LED light will emitted the light after the printing starts.
•
The LED light will be automatically shut down if any of the protective cover is open.
NOTE ON POWER SUPPLY
•
Do not use with damaged cord or plug. To unplug grasp the plug, not the cord. Do not handle plug or
machine with wet hands. Turn off the power switch before unplugging.
•
Do not run the machine over cord. Keep cord away from heated surfaces.
•
If the system is left in idle mode for an extended amount of time, turn off the main switch.