Xylem WTW SenTix ORP-T 900 Скачать руководство пользователя страница 11

SenTix

®

ORP-T 900(-P)

Wear parts and accessories

11

ba75845e03

02/2017

8

Wear parts and accessories

9

Disposal

At the end of its operational lifetime, the electrode must be returned to the 
disposal or return system statutory in your country (electronic waste). If you 
have any questions, please contact your supplier.

Maintenance

equipment

Description

Model

Order no.

Reference electrolyte solution 3 mol/l KCl, 
Ag

+

 free (250 ml)

KCl-250

109 705

Reagent set for regenerating ORP platinum 
electrodes, consisting of 10 g activation 
powder and 30 g clorina powder

SORT/RH

109 730

ORP buffer solution for checking ORP 
electrodes U

H

 = 427 mV, bottle of 250 ml

RH 28

109 740

Pepsin cleaning solution, 3 bottles of 250 ml 
each

PEP/pH

109 648

Connection

cableSenTix

®

ORP

-T 900(-P) - meter

Description

Model

Order no.

IDS connection cable, 1.5 m

AS/IDS-1.5

903 850

IDS connection cable, 3 m

AS/IDS-3

903 851

IDS connection cable, 6 m

AS/IDS-6

903 852

IDS connection cable, 10 m

AS/IDS-10

903 853

IDS connection cable, 15 m

AS/IDS-15

903 854

IDS connection cable, 20 m

AS/IDS-20

903 855

IDS connection cable, 25 m

AS/IDS-25

903 856

IDS connection cable, 40 m

AS/IDS-40

903 857

IDS connection cable, 60 m

AS/IDS-60

903 858

IDS connection cable, 100 m

AS/IDS-100

903 859

General

accessories

Description

Model

Order no.

Blind plug for IDS plug

BPO/IDS 900

908 371

Armoring without protective hood

A 925-P

903 838

Armoring with plastic protective hood

A 925-P/K

903 839

Armoring with steel protective hood

A 925-P/S

903 840

Plastic arming for SenTix

®

ORP-T 900(-P) 

pH electrodes

A pHLab/K

903 841

Содержание WTW SenTix ORP-T 900

Страница 1: ...ba75845e03 02 2017 SenTix ORP T 900 P ORP ELECTRODE SenTix ORP T 900 P OPERATING MANUAL For Sales Service Contact 2650 E 40th Ave Denver CO 80205 Phone 303 320 4764 Fax 303 322 7242 1 800 833 7958 ww...

Страница 2: ...2 ba75845e03 02 2017 SenTix ORP T 900 Copyright 2017 Xylem Analytics Germany GmbH Printed in Germany...

Страница 3: ...is connected and is used for measurement and for measured value documentation Storing the calibration data in the sensor ensures that the correct slope and asymmetry are automatically used if the sen...

Страница 4: ...and index finger to press the clips of the connector together and pull the connector out of the plug step 2 Closing the plug connection Make sure that the plug connection is completely dry and clean...

Страница 5: ...l of the meter and observe the following rules while doing so Preparing the sensor for measurement 2 3 General rules for measuring Make sure the refilling opening for the reference electrolyte solutio...

Страница 6: ...orrect The junction must be com pletely submersed in the solution The junction is in the area of the bottom end of the shaft see arrow At the same time the level of the reference electrolyte must be a...

Страница 7: ...horten the lifetime of the electrode These are Strong acids or lyes hydrofluoric acid organic solvents oils fats bro mides sulfides iodides proteins High temperatures High changes in pH and temperatur...

Страница 8: ...e tip of the dropping bottle into the refilling opening while turning it slightly Pump several small quantities of the reference electrolyte into the stem using the dropper bottle Pull the dropping bo...

Страница 9: ...value and the ORP voltage UH of the test solution where the latter must be estimated for the first measurement The type of pretreatment can then be determined using the following diagram where UH is b...

Страница 10: ...Platinum circle Connection cable Lengths SenTix ORP T 900 1 5 m SenTix ORP T 900 P 1 5 3 6 10 15 25 40 60 100 m Diameter 4 3 mm Smallest allowed bend radius Fixed installation 20 mm Flexible use 60 mm...

Страница 11: ...ion 3 bottles of 250 ml each PEP pH 109 648 Connection cableSenTix ORP T 900 P meter Description Model Order no IDS connection cable 1 5 m AS IDS 1 5 903 850 IDS connection cable 3 m AS IDS 3 903 851...

Страница 12: ...Disposal SenTix ORP T 900 P 12 ba75845e03 02 2017...

Страница 13: ......

Страница 14: ...buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications...