5 Installation
5.1 Precautions
Before starting work, make sure that the safety instructions in the chapter
on page 3 have been read and understood.
WARNING:
All work must be performed by qualified personnel trained in the proper application,
installation, and maintenance of the equipment.
WARNING:
Always disconnect and lock out power to the sensor before you perform any installation or
maintenance tasks. Failure to disconnect and lock out power will result in serious physical
injury or property damage.
WARNING:
Failure to follow all instructions can result in a fire hazard which may cause personal injury or
property damage.
WARNING:
Magnetic Hazard. Magnetic fields can damage cardiac pacemaker and other medical
implants.
WARNING:
The magnets in the sensor feet are extremely powerful. Beware of serious injury to fingers
and hands. When not in use, keep magnetic (ferrous) components and magnetized tools
apart by a minimum of 1 m (3 ft).
5.2 Mounting options
One of the following mountings must be used to install the sensor on a pump or motor:
Standard magnetic mounting
Flat plate mounting
5.3 Requirements
5.3.1 Standard magnetic mounting
• The standard magnetic mounting must be installed on ferrous metals.
• The sensor must be mounted near bearings or other sources of vibration and increase in
temperature.
• The standard magnetic mounting cannot be installed on special alloys or stainless steels.
• Before the sensor is installed, the pump or motor surface must be cleaned.
• If there is no correct surface to install the standard magnetic mounting, use the flat plate
mounting.