Additional Installation, Operation and 

Maintenance Instructions 

 

 

Genyo plus 

Electronic pressure switch 

Содержание Lowara Genyo plus

Страница 1: ...Additional Installation Operation and Maintenance Instructions Genyo plus Electronic pressure switch...

Страница 2: ...spection of the unit 7 2 3 Storage 7 3 Technical Description 9 3 1 Designation 9 3 2 Data plate 9 3 3 Identification code 10 3 4 Names of the main components 10 3 4 1 Control panel 11 3 4 2 LEDs descr...

Страница 3: ...ter set 27 7 Maintenance 28 7 1 Precautions 28 7 2 Maintenance every 3 months of operation 28 7 3 Spare parts ordering 28 8 Troubleshooting 29 8 1 Precautions 29 8 1 1 Alarms 29 8 2 Alarm A01 lack of...

Страница 4: ...on pumps may be supplied with supplementary instruction manuals For situations not considered in the manual or in the sales document contact Xylem or the Authorised Distributor 1 2 Safety 1 2 1 Danger...

Страница 5: ...s this product may be used by children aged 8 years and above and persons with reduced physical sensory or mental capabilities or who lack experience and knowledge provided that they are being supervi...

Страница 6: ...e current regulations on sorted waste disposal 1 2 4 Sites exposed to ionizing radiations WARNING Ionizing radiation hazard If the unit has been exposed to ionizing radiations implement the necessary...

Страница 7: ...port document or reject the goods indicating the reason on the transport document In both cases promptly contact Xylem or the Authorised Distributor from whom the product was purchased 2 2 2 Unpacking...

Страница 8: ...lation Operation and Maintenance Instructions Long term storage of the unit Follow the same instructions for the storage of the packed unit For further information about preparation for long term stor...

Страница 9: ...number Description 1 Power Supply Voltage 12 Hardware version 2 Frequency 13 Maximum liquid pressure 3 Maximum current of the pump unit 14 Maximum differential 4 Maximum motor power 15 Minimum differe...

Страница 10: ...rrent of the pump unit A 4 Voltage supply range 50 60Hz V 3 4 Names of the main components Position number Description Position number Description 1 Cable gland of the Uin power supply cord 6 Screws o...

Страница 11: ...ator of the current A measurement unit see also LEDs description 5 Button for viewing on the display pressure in bar or pressure in psi or absorbed current in Ampere 6 Button for selecting the operati...

Страница 12: ...pump unit stopped Slow flashing STOP pressure being modified The display flashes and shows the pressure Steady STOP pressure set Slow flashing START pressure being modified Steady START pressure set...

Страница 13: ...flammable and or explosive liquids DANGER Potentially explosive atmosphere hazard It is prohibited to start the unit in environments with potentially explosive atmospheres or with combustible dusts Ex...

Страница 14: ...personal protective equipment WARNING Always use suitable working tools WARNING When selecting the place of installation and connecting the unit to the hydraulic and electric power supplies strictly...

Страница 15: ...enyo plus unit 3 Electric panel 7 Pressure gauge 4 On off valve 8 Drain tap 1 Remove any welding residues deposits and impurities in the pipes that could damage the unit 2 Install an on off valve betw...

Страница 16: ...e unit on the piping putting sealant on the thread Mounting positions 4 4 Electrical connection DANGER All the hydraulic and electrical connections must be completed by a technician possessing the tec...

Страница 17: ...Guidelines for the electrical control panel NOTICE The electric panel must match the ratings on the unit data plate Improper combinations could damage the motor Install an overload circuit breaker wi...

Страница 18: ...Insert the Uout motor power supply cord in cable gland 2 5 Insert the cores of the conductors in the respective holes and tighten the screws Tightening torque 1 2 Nm 10 6 lbf in 6 Put the cover back i...

Страница 19: ...motor see Setting the current on page 20 Set the P START and P STOP pressure values see Setting the P START and P STOP pressure values on page 21 Open the on off valve on the delivery line Start the p...

Страница 20: ...llowed by the instantaneous pressure value bar or psi 2 Press several times to view in alternation the pressure bar or psi or the instantaneous current A 5 2 3 Setting the current Set the nominal abso...

Страница 21: ...ial start up or after modifying the conditions of installation The calibrated P START and P STOP pressure values are shown in the diagram Note P START P STOP 0 1 MPa 1 bar 14 5 psi Setting the P START...

Страница 22: ...nd Maintenance Instructions 3 Edit the value 4 Confirm Setting the P STOP Phase Action Illustration 1 With the unit in OFF or AUT mode press several times to view the pressure bar or psi 2 Press once...

Страница 23: ...zation and setting of the parameter menu Phase Action Illustration 1 Press once 2 Press and hold for a while to enter the parameter menu see Programming on page 24 3 Press several times to select the...

Страница 24: ...nt for pressure bar psi bar 2 Protection of maximum number of starts of the motor rc0 disabled rc1 with alarm triggered start is delayed by 5 s to protect the pump unit rc2 with alarm triggered the pu...

Страница 25: ...r psi bar psi D0 5 Can be activated with use of the booster set parameter 5 set to U01 or U02 The value must be the same for both unit U01 and unit U02 See figure 3 6 Delay time till starting of the p...

Страница 26: ...d P0 0 disabled P8 0 8 bar psi bar psi 0 0 Alarm A11 is triggered if the pressure does not reach the set value If not set at 0 0 activation of the ART function see The ART function on page 26 10 1 Del...

Страница 27: ...nd P STOP must be 0 1 MPa 1 bar 14 5 psi Minimum P START pressure of the parameter 5 1 0 5 bar 7 3 psi 2 Enter the parameter menu see Visualization and setting of the parameter menu on page 23 3 Set p...

Страница 28: ...ls WARNING In the case of liquids that are excessively hot or cold pay attention to the risk of injury DANGER Electrical hazard Before starting work check that the unit is unplugged and that the pump...

Страница 29: ...Press the MENU ENTER button 6 or 1 Disconnect the power supply 2 Wait 1 minute 3 Turn on the power supply 8 2 Alarm A01 lack of water via the software LED Cause Solution Steady Lack of water Pump uni...

Страница 30: ...Solution Steady Pressure below the minimum threshold Check setting of parameter 10 Slow flashing Pressure below the minimum threshold ART function activated No flow of water Check the water level and...

Страница 31: ...0 1 to 0 8 MPa 1 to 8 bar 14 5 to 116 psi Maximum differential 0 75 MPa 7 5 bar 109 psi Minimum differential 0 05 MPa 0 5 bar 7 3 psi Maximum pressure PN 0 8 MPa 8 bar 116 psi Fluid connection Rp Wei...

Страница 32: ...avors the re use and or recycling of the materials it is composed of the equipment Waste from private household Please contact your municipality or local authority for all information regarding the se...

Страница 33: ...ty with the relevant Union harmonization legislation 2014 35 EU Directive of 26 February 2014 electrical equipment designed for use within certain voltage limits and subsequent amendments 2014 30 EU D...

Страница 34: ...iginal instructions 34 Genyo plus Additional Installation Operation and Maintenance Instructions 12Warranty 12 1 Information For information on the warranty refer to the documentation of the sale cont...

Страница 35: ...en Original instructions Genyo plus Additional Installation Operation and Maintenance Instructions 35...