Xylem JABSCO 18660 Series Скачать руководство пользователя страница 1

OPERATION

Flexible impeller pumps must

NOT be run dry, as the

pumped liquid is the lubricant for the impeller. Observe
the outlet and shut off pump as soon as liquid stops
flowing. An automatic level switch is convenient to
control the pump.
The pump cannot run against a closed outlet such as
encountered when using a garden hose type shut-off
nozzle.
Pressure for normal operation should not exceed 20 feet
of head (8.7 psi).
Temperature of pumped liquid may be in the range of
45° - 180°F (7° - 82°C).

SELF-PRIMING PUMP

FEATURES

Motor:

Permanent magnet type, fully
enclosed, stainless steel shaft.

Dimensions:

3" (76mm) high, 6-3/8" (162mm)
long, 4-3/4" (120mm) wide

Weight:

4-1/2 lb (2 kg) (approx.)

Body:

Bronze

Impeller:

Jabsco Neoprene compound

Seal:

Lip type

Ports:

1/2" Internal Pipe Threads
1" External Hose Barb
Adapter for 3/4" External Garden
Hose Thread included

Motor meets USCG Electrical Standards 183.410 and
ISO 8846 MARINE for IGNITION PROTECTION on
gasoline powered vessels.

APPLICATION

Use for bilge pumping, livewell circulation, washdown
and general pumping requirements. If bilge water
contains significant amount of oil, the standard impeller
should be replaced with impeller No. 6303-0003, which is
an oil-resistant nitrile material.
Pump has a dry prime suction lift of about 4 feet (1.2m)
and a lift to 20 feet (6m) when primed. BE SURE
SUCTION LINES ARE AIRTIGHT.

WARNING

!

Explosion hazard. Do not pump 

gasoline, solvents, thinners or other 

flammable liquids. To do so can cause

an explosion resulting in injury or death.

Light housing gets hot during 

operation.  Do not touch during 

or immediately after operation.  

Burns can result.

WARNING

!

Motor runs hot—about 180° is a normal
temperature. Prolonged contact during
operation may cause a burn.

M

o

d

e

l

1

8

6

6

0

-0

1

2

1

Model 18660-0121

Содержание JABSCO 18660 Series

Страница 1: ...Hose Barb Adapter for 3 4 External Garden Hose Thread included Motor meets USCG Electrical Standards 183 410 and ISO 8846 MARINE for IGNITION PROTECTION on gasoline powered vessels APPLICATION Use for bilge pumping livewell circulation washdown and general pumping requirements If bilge water contains significant amount of oil the standard impeller should be replaced with impeller No 6303 0003 whic...

Страница 2: ...a 15 amp rating with a wire from switch or breaker to positive terminal of battery Electrical circuit must be independent of all other accessories Failure to connect black wire to negative and orange wire to positive will result in backwards motor rotation and possible motor and pump damage Correct motor rotation is clockwise looking at shaft end of motor Use proper wire size as determined by wire...

Страница 3: ...ing motor rotation and causing blown fuses To correct remove end cover and impeller clean body and impeller then lubricate with water or small amounts of grease before assembly If pump is to be in freezing temperatures drain by loosening end cover screws A Service Kit or at least spare impellers should be carried aboard to be assured of pumping capability DISASSEMBLY 1 Remove end cover screws end ...

Страница 4: ...are ready to ship whichever shall occur first unless a longer period is specified in the product documentation the ìWarran tyî Except as otherwise required by law Seller shall at its option and at no cost to Buyer either repair or replace any product which fails to conform with the Warranty provided Buyer gives written notice to Seller of any defects in material or workmanship within ten 10 days of ...

Отзывы: