![Xylem Flygt 2840.180 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/xylem/flygt-2840-180/flygt-2840-180_installation-operation-and-maintenance-manual_3870241018.webp)
The seal sleeve and the washers must conform to the outside diameter of the cables.
WARNING:
Do not install the starter equipment in an explosive zone unless it is explosion-proof rated.
Cable charts
Connection locations
WS001021B
L1 L2 L3
T3 T4
T1 T2
15
13
14
4
2
3
1
7
10
5
9
8
6
11
12
17
16
24
22
23
19
20
21
18
1
Starter equipment and main leads (L1, L2, L3)
13
Coil
2
Earth (ground)
14
Transformer
3
Functional ground
15
Capacitor
4
Control leads (T1, T2, T3, T4)
16
Softstarter
5
Phase shifter
17
Level regulator
6
Diode
18
Contactor, start relay or thermal relay
7
Motor cable
19
Thermal detector in stator
8
Screen
20
Thermal detector in main bearing
9
Pump
21
Jumper
10
Crimp connection
22
Terminal board, terminal plate
11
Crimp isolation
23
Leakage sensor
12
Motor protector
24
Stator leads (U1, U2, U5, U6, V1, V2, V5, V6, W1,
W2, W5, W6, Z1, Z5, Z6)
Color code standard
Code
Description
BN
Brown
BK
Black
WH
White
OG
Orange
Installation
16
Flygt 2840.180 Installation, Operation, and Maintenance Manual
Содержание Flygt 2840.180