6 Technical Reference
6.1 Application limits
Data
Description
Media (liquid) temperature
Maximum 40°C (104°F)
Standard version option, Warm media (liquid) version:
Maximum temperature 70°C (158°F).
Warm liquid has certain operational limitations, which
are stated on a plate on the pump.
pH of the pumped media (liquid)
5–8
Media (liquid) density
1100 kg/m³ (9.2 lb per US gal) maximum
Depth of immersion
Maximum 20 m (65 ft)
Maximum permissible working pressure
2.8 bar (40.6 psi)
Other
For the specific weight, current, voltage, power ratings,
and speed of the pump, see the data plate of the pump.
For other applications, contact a sales or authorized
service representative for information.
6.2 Motor data
Feature
Description
Motor type
Squirrel-cage induction motor
Frequency
Standard version: 50 or 60 Hz
MSHA version: 60 Hz
Supply
1-phase or 3-phase
Starting method
Direct on-line
Maximum starts per hour 30 evenly-spaced starts per hour
Code compliance
IEC 60034-1
Voltage variation without
overheating
±10%, if it does not run continuously at full load
Voltage imbalance
tolerance
2%
Stator insulation class
F (155°C [311°F])
Motor encapsulation
Motor encapsulation is in accordance with IP68.
6.3 Specific motor data
1-phase, 50 Hz
Motor type:
• 2,830 rpm
• 1.5 kW (2.0 hp)
Voltage, V
Rated current, A
Starting current, A
Power factor, cos
φ
220
8.7
31
0.99
230
8.4
32
0.98
240
8.3
34
0.96
6 Technical Reference