Adjust the impeller
In order for the pump to perform at maximum capacity, the impeller must be adjusted
regularly. The impeller clearance should be minimal when the impeller is tightened. Use
the adjusting washers to adjust the clearance.
Version code 324: Pumps equipped with polyurethane covering are extremely resistant to
wear. If the impeller does not rotate completely freely, the friction will generate a lot of
heat. This can result in deformed wear parts, a stuck impeller, or damage to the pump. The
impeller clearance should be 0.2–0.3 mm (0.008–0.012 in.) when the impeller is tightened.
NOTICE:
On the warm media (liquid) version (2075.324 option), the clearance between the impeller
and the oil casing bottom/lower diffuser must be at least 0.3 mm (0.01 in.). This is because
the rubber lining swells slightly at high temperatures.