Xylem Flygt 2008 Ready 8 Скачать руководство пользователя страница 19

Code

Description

YE

Yellow

Motor cable and starter unit connection to the terminal board

1 - P H A 

S E (1~)

Connection plate

2004

2008

BN
BU
GNYE

Motor cable

Pump

Capacitor

WH

WH

WH

BN
BK

With capacitor

M

Motorswitch

Float switch

Optional

GC

GNYE

BN/BK

BU/WH

3

1

Stator

COLOUR STANDARD

AND SYMBOLS

BN=Brown

BK=Black

BU=Blue

WH=White

GNYE=Green-Yellow 

M

Ground

Terminal device

GC

Ground check

Connector

Inside pump

788 24

 00

BU

WS007753

4.3  Check the impeller rotation

CAUTION: Crush Hazard

The starting jerk can be powerful. Make sure nobody is close to the unit when it is started.

Check the direction of rotation each time the cable has been re-connected and after
phase or total supply failure.
1. Start the motor.
2. Stop the motor.
3. Check that the impeller rotates in the correct direction.

The correct direction of impeller rotation is clockwise when you look at the pump from
above. When started, the pump will react in the opposite direction to the impeller
rotation.

WS001398B

Figure 3: Start reaction

4. If the impeller rotates in the wrong direction, then do the following:

– If the motor has a 1-phase connection, then contact a sales or authorized service

representative.

4  Installation

2008 Ready 8, 8S Installation, Operation, and Maintenance

17

Содержание Flygt 2008 Ready 8

Страница 1: ...Installation Operation and Maintenance 898397_4 0 2008 Ready 8 8S...

Страница 2: ......

Страница 3: ...8 3 4 The data plate 9 3 5 Product denomination 10 4 Installation 11 4 1 Install the pump 11 4 1 1 Install with S installation 12 4 2 Make the electrical connections 13 4 2 1 Connect the motor cable...

Страница 4: ...sequence 33 7 4 The pump runs but the motor protection trips 33 7 5 The pump delivers too little or no water 34 8 Technical Reference 36 8 1 Application limits 36 8 2 Motor data 36 8 3 Specific motor...

Страница 5: ...nts and information in the original manufacturer s manuals for any other equipment furnished separately for use in this system 1 2 Safety terminology and symbols About safety messages It is extremely...

Страница 6: ...such as mining or construction have a dynamic nature and require temporary installation of equipment Due to the rugged nature of these applications normal use of electrical equipment causes wear and...

Страница 7: ...disposal Observe the local regulations and codes regarding Reporting of emissions to the appropriate authorities Sorting recycling and disposal of solid or liquid waste Clean up of spills Exceptional...

Страница 8: ...tive if there is any issue 2 2 Transportation guidelines Precautions DANGER Crush Hazard Moving parts can entangle or crush Always disconnect and lock out power before servicing to prevent unexpected...

Страница 9: ...e liquid into a surrounding temperature below freezing Follow these guidelines to avoid freezing damage 1 Empty all pumped liquid if applicable 2 Check all liquids used for lubrication or cooling both...

Страница 10: ...ion about pH see Technical Reference on page 36 Particle size Version code 281 The pump can handle liquid containing particles that correspond to the pump housing inlet The diameter of the pump housin...

Страница 11: ...on to eliminate the level regulator function Illustration 1 2 WS006210B 1 On 2 Off Figure 1 The functionality of the level regulator 3 4 The data plate Introduction The data plate is located on the ma...

Страница 12: ...git The different types of codes are marked up with a b and c Code parameters are marked up with numbers Codes and parameters XXYYYY YYY YYY YYYY 1 2 3 4 5 6 7 a b c WS006265B Type of Callout Number I...

Страница 13: ...ion proof or intrinsically safe If the product is EN ATEX MSHA or FM approved then see the specific EX information in the Safety chapter before taking any further actions WARNING Explosion Fire Hazard...

Страница 14: ...able and intended to operate either completely or partially submerged in the pumped liquid The pump is equipped with a connection for hose or pipe These requirements and instructions only apply when t...

Страница 15: ...ake sure that electrical connections have been correctly made WARNING Crush Hazard Risk of automatic restart CAUTION Electrical Hazard Prevent cables from becoming sharply bent or damaged NOTICE Leaka...

Страница 16: ...r SUBCAB cables the twisted pair copper foil must be trimmed All unused conductors must be insulated Grounding earthing Grounding earthing must be done in compliance with all local codes and regulatio...

Страница 17: ...to ground earth 4 Firmly tighten the cable entry into its bottom most position The seal sleeve and the washers must conform to the outside diameter of the cables DANGER Explosion Fire Hazard Special r...

Страница 18: ...r 6 Diode 18 Contactor start relay or thermal relay 7 Motor cable 19 Thermal detector in stator 8 Screen 20 Thermal detector in main bearing 9 Pump 21 Jumper 10 Crimp connection 22 Terminal board term...

Страница 19: ...Make sure nobody is close to the unit when it is started Check the direction of rotation each time the cable has been re connected and after phase or total supply failure 1 Start the motor 2 Stop the...

Страница 20: ...not evaluated this unit for use in swimming pools If used in connection with swimming pools then special safety regulations apply Noise level NOTICE The sound power level of the product is lower than...

Страница 21: ...rush Hazard Never put your hand into the pump housing 4 Check that the monitoring equipment if any works 5 Check that the impeller rotation is correct 6 Start the pump 5 3 Clean the pump The pump must...

Страница 22: ...components have been thoroughly cleaned Make sure that the work area is well ventilated before you open any vent or drain valves remove any plugs or disassemble the unit Do not open any vent or drain...

Страница 23: ...ads For hexagon socket head screws with countersunk head maximum torque for all property classes must be 80 of the values for property class 8 8 above 6 2 Service Regular service of the pump ensures m...

Страница 24: ...Air inside the chamber may cause parts or liquid to be propelled with force Be careful when opening Hold a rag over the plug to prevent liquid from spraying out 3 Turn the pump so that the oil hole f...

Страница 25: ...rts can have sharp edges Wear protective clothing 1 Remove the strainer WS002031A 3x 2 Remove the diffuser WS002032A 3 Remove the impeller a Remove the impeller screw and washer b Pull off the impelle...

Страница 26: ...Hazard Worn parts can have sharp edges Wear protective clothing 1 Remove the pump housing unit WS002030B 3x 2 Remove the impeller a Remove the impeller screw and washer b Pull off the impeller 6 Main...

Страница 27: ...d This is to prevent the shaft from rotating with the impeller screw 3 Fasten the impeller a Place the washer on the impeller screw b Mount the impeller Make sure that the impeller hub disk center is...

Страница 28: ...ft must be clean and free from burrs 2 Check that the impeller screw is clean and easy to screw into the shaft end This is to prevent the shaft from rotating with the impeller screw 3 Fasten the impel...

Страница 29: ...ing torque 9 3 Nm 6 9 ft lbs d Check that the impeller can rotate freely 4 Mount the pump housing unit WS002030B 3x 5 Tighten the screw s Tightening torque 9 3 Nm 6 9 ft lbs 6 Maintenance 2008 Ready 8...

Страница 30: ...cable entry WS003053A 2 Remove the pump top 3x WS003054A 3 Disconnect the motor cable from the terminals a Disconnect the power lead s b Disconnect the ground earth lead s 4 Remove the motor cable 6...

Страница 31: ...the terminals See Make the electrical connections on page 13 If the cable is damaged then cut off the damaged part and install new terminals a Connect the ground earth lead s b Connect the power lead...

Страница 32: ...3x WS003056A 4 Tighten the cable entry Make sure that it bottoms out WS003053A 6 Maintenance 30 2008 Ready 8 8S Installation Operation and Maintenance...

Страница 33: ...wer before servicing to prevent unexpected startup Failure to do so could result in death or serious injury E q u ip m e n t lo c k e d o u t b y N a m e D A N G E R NOTICE Do NOT override the motor p...

Страница 34: ...r before servicing to prevent unexpected startup Failure to do so could result in death or serious injury E q u ip m e n t lo c k e d o u t b y N a m e D A N G E R Cause Remedy The pump is unable to e...

Страница 35: ...page 8 7 4 The pump runs but the motor protection trips DANGER Crush Hazard Moving parts can entangle or crush Always disconnect and lock out power before servicing to prevent unexpected startup Failu...

Страница 36: ...t see Product Description on page 8 7 5 The pump delivers too little or no water DANGER Crush Hazard Moving parts can entangle or crush Always disconnect and lock out power before servicing to prevent...

Страница 37: ...r is set correctly Depending on the installation type add a means for priming the pump such as a foot valve If the problem persists then contact a sales or authorized service representative Always sta...

Страница 38: ...Motor type Squirrel cage induction motor Frequency 50 Hz or 60 Hz Supply 1 phase Maximum starts per hour 15 evenly spaced starts per hour Code compliance IEC 60034 1 Voltage variation without overhea...

Страница 39: ...0 Hz Motor type 2 800 rpm 900 W 1 2 hp Voltage V Rated current A Starting current A 115 11 43 230 5 2 19 240 5 20 1 phase 60 Hz Motor type 3 330 rpm 820 W 1 1 hp Voltage V Rated current A Starting cur...

Страница 40: ...5 Dimensions and weights Ready 8 WS001176A A B A 438 mm 17 2 in B 184 mm 7 2 in Weight without motor cable 14 5 kg 32 lb 8 Technical Reference 38 2008 Ready 8 8S Installation Operation and Maintenanc...

Страница 41: ...mm 7 8 in C 263 mm 10 4 in Weight without motor cable 17 kg 37 lb 8 6 Performance curves Test standard Pumps are tested in accordance with ISO 9906 2012 HI 11 6 2012 8 Technical Reference 2008 Ready...

Страница 42: ...Ready 4 Ready 4L WS006426B Ready 4L Ready 4 Figure 4 50 Hz 0 1 2 3 4 5 6 0 20 40 60 80 100 0 2 4 6 8 10 12 14 0 10 20 30 40 50 0 0 0 2 0 4 0 6 0 8 1 0 0 0 0 5 1 0 1 5 Ready 8S Ready 8S Ready 8 Ready...

Страница 43: ......

Страница 44: ...k technologies and advanced data analytics for water gas and electric utilities to its portfolio of solutions In more than 150 countries we have strong long standing relationships with customers who k...

Отзывы: