![Xylem Flygt 2008 Ready 8 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/xylem/flygt-2008-ready-8/flygt-2008-ready-8_installation-operation-and-maintenance-manual_4107150010.webp)
3 Product Description
3.1 Products included
Pump model
Standard
EX
MSHA
Drainage
Sludge
Ready 8, 2008.212
X
X
Ready 8S, 2008.281
X
X
3.2 Pump design
The pump is submersible, and driven by an electric motor.
Intended use
The product is intended for moving waste water, sludge, raw and clean water. Always
follow the limits given in
on page 36. If there is a question regarding
the intended use of the equipment, then contact a sales or authorized service
representative before proceeding.
DANGER: Explosion/Fire Hazard
Special rules apply to installations in explosive or flammable atmospheres. Do not install
the product or any auxiliary equipment in an explosive zone unless it is rated explosion-
proof or intrinsically-safe. If the product is EN/ATEX-, MSHA- or FM-approved, then see
the specific EX information in the Safety chapter before taking any further actions.
on page 36.
Particle size
Version code 281: The pump can handle liquid containing particles that correspond to
the pump housing inlet. The diameter of the pump housing inlet is 38 mm (1.5 in).
Version code 212: The pump can handle liquid containing particles that correspond to
the holes in the strainer.
Number of holes
Hole dimensions
Version code 212: 96
11×5 mm (0.43×0.2 in)
Pressure class
MT
Medium head
Impeller type
Version code 212: B
Wear resistant
Version code 281: D
Sludge
3.3 Monitoring equipment
The following applies to the monitoring equipment of the pump:
• The stator incorporates thermal contacts connected in series that activate the alarm at
overtemperature.
• The thermal contacts open at 135°C (275°F).
3.3.1 Level regulators
About level regulators
Starting and stopping the pump at different water levels can be manual or automatic. If
automatic start and stop is required, a level regulator can be ordered (as an option). The
option is only available for standard pumps.
3 Product Description
8
2008 Ready 8, 8S Installation, Operation, and Maintenance