4.3 Rotate the pump
1
2
1
1
WS013751B
3
4
1. Crane hook
2. Lifting straps
3. Pump housing
4. Frame
1. Attach a crane hook to the pump handle.
2. Attach straps between the pump housing and a second crane.
3. Lift the pump in the pump handle.
4. By using the cranes, rotate the pump to a horizontal position.
5. Install the pump in the frame and tighten all fasteners.
Install the discharge cone and the inlet cone.
4.4 Install the pump
Consult the nearest local sales and service representative regarding the following:
• Sizing of the pump, piping station, and access frame
• Choice of auxiliary equipment
• Other aspects of installation
NOTICE:
Do not run the pump dry.
NOTICE:
Never force piping to make a connection with a pump.
Before installation, check the following:
• An applicable cable support and protection system is used.
• The propeller rotates in the correct direction.
If the rotation is not in the correct direction, then the pump can lift and start rotating inside
the tube. This movement can seriously damage the equipment.
• The rubber seal ring underneath the pump is in position.
• There is no damage to, or unwanted material on, the pump seat.
4 Installation
P7900 Installation, Operation, and Maintenance Manual
23