On receiving

 your Flojet diaphragm pump 

check that the pump and model number and 
motor volts/phase/Hz correspond to your 
purchase order.  Notify your supplier 
immediately in the event of any error, or of 
damage to the pump on receipt.  Delay may 
cause difficulty with warranty claims. 

Installation.  

Locate the pump in a dry 

place above or below the liquid supply.  The 
pump will self-prime when wetted to a height 
not exceeding 2 metres.  The pump may be 
mounted in any attitude.  If mounted 
vertically, the motor should be uppermost.  
The drain holes in the pump body should face 
downwards: if necessary, undo the 4 body 
screws and rotate the pump head through 90º 
or 180º.  Attach the pump to a firm surface 
with fixing screws through the mounting feet. 

Connections.  

Port adapters available are 

13mm (½”) hose barb and ½” NPT threaded.  
Use hose clips for hose connections and 
PTFE tape for threaded connections.  
Flexible hose is recommended.  Inlet hose 
should be at least 13mm (½”) bore, of the 
reinforced type that will not deform or 
collapse under suction conditions.  

A ‘Pumpguard’ strainer is recommended to 
prevent solid debris from entering the pump.  
The strainer should be checked at intervals 
and cleaned when necessary.  See Cleghorn 
Waring’s data sheet for details of 
‘Pumpguard’ strainers and port fittings. 

Make sure that the inlet and discharge pipes 
and connections are airtight, to ensure 
prompt self-priming and no leaks. 

Electrical connection.

  The unit is 

complete with a standard European single 
phase 3 wire lead.  Check the motor plate for 
the correct electrical supply and full load 
current.  Make sure that the motor (and 
adjustable pressure switch, if fitted) are 
earthed. A starter with thermal overload 
protection should be used to protect the 
motor.    A COMPETENT ELECTRICIAN 
SHOULD DO THE WIRING.   

Controlling the discharge pressure

.

  

The maximum recommended discharge 
pressure is 3.0 bar (45 p.s.i.).  The pump is a 
positive displacement type that can be 
damaged by excessive back pressure. 

Installation, 
Operating, 
Maintenance and 
Safety 

INSTRUCTIONS 

for 

CW474 - series

 

DIAPHRAGM PUMP 
with a.c. motor

 

 

 

 

 

Xylem Water Solutions UK Ltd 
Bingley Road 
Hoddesdon 
Hertfordshire • EN11 0BU • UK 

Tel: +44 (0)1462 480380 
Fax: +44 (0)1462 482422 
[email protected] 
www.jabscoshop.com 

 
 
 
 
 

Doc610/12 

 

Отзывы: