Cause
Remedy
Mechanical seal damaged due to chemical
incompatibility with the liquid
Replace the mechanical seal with one of a make
chemically compatible with the pumped liquid
7.12 The motor becomes excessively hot
Cause
Remedy
Room temperature outside the rated limits
Lower the room temperature
Cooling fan of the motor clogged or damaged
Clean or replace the cooling fan
The pump unit starts up too frequently
See Part 7.8
The frequency converter, if present, has not been
calibrated properly
See the frequency converter manual
7.13 The frequency converter (if present) is in error mode or turned off
Cause
Remedy
See the frequency converter manual
See the frequency converter manual
7 Troubleshooting
Series e-80SCXL INSTRUCTION MANUAL
31
Содержание Bell & Gossett e-80SCXL Series
Страница 1: ...INSTRUCTION MANUAL P2005589 A Series e 80SCXL...
Страница 2: ......