X-45C1-01-30 Rev 1
6
and adjusting this parameter for optimum spectral symmetry. Please refer to
the transceiver technical manual for further information.
3) Adjust TX D/A
This adjustment may be used to fine-tune the transmit frequency. Typically,
this alignment is accomplished by placing the unit in CW Mode and monitoring
the signal with a frequency counter to ensure that the transmitter is correctly
tuned. Please refer to the transceiver technical manual for further information.
4) RX/CW/Data/Off
This feature may be used to switch transceiver though various operational
modes.
CAUTION:
The transceiver is designed to operate at a maximum 50%
Transmit/Receive duty cycle. Overheating and equipment failure
may occur if the
CW
or
Data
modes are left on for extended periods
of time.
5) Change Frequency
This function allows the operator to set the current transmit/receive frequency.
The frequency will adjust in steps of 50 kHz to 500 kHz depending on the unit
configuration database settings.
6) Change Baud
This feature allows the operator to toggle between 4800 and 9600 Baud.