X-45C1-01-30 Rev 1
4
2) Radio CW
Activating this mode will cause the transceiver to key-up. No data will be
applied to modulate the signal. This function will time out after approximately
3 minutes to protect the transceiver. The unit will revert to
Receive Mode
after
the time-out.
CAUTION:
The transceiver is designed to operate at a maximum 50%
Transmit/Receive duty cycle. Overheating and equipment failure
may occur if the
Radio CW
mode is repeatedly activated.
3) Transmit Data
Activating the Transmit Data mode will cause the unit to continuously transmit
an ASCII data pattern. This function will time out after approximately 3
minutes to protect the transceiver. The unit will revert to
Receive Mode
after
the time-out.
CAUTION:
The transceiver is designed to operate at a maximum 50%
Transmit/Receive duty cycle. Overheating and equipment failure
may occur if the
Transmit Data
mode is repeatedly activated.
4) Radio Off
This mode will shut off the power supplies to both the Transmitter and Receiver
sections of the transceiver.
5) Normal Operation
Normal Operation
Mode will cause the unit to behave as it normally does during
operation. This involves transmitting an approximately 90-byte message at
regular intervals, then reverting back to receive. The message intervals are as
follows:
Model
Application
Typical Message Interval
M-45C1-01
Handheld Golfer Unit
twice per minute
B-45C1-01
Base/Repeater Unit
once per second