USM: V1.0 

 

Содержание XG2

Страница 1: ...XG2 User Manual USM V1 0 ...

Страница 2: ...emarks are the property of their respective owners Warranty Xtramus Technologies warrants to recipient that hardware supplied with this document will be free from significant defects for a period of three 3 months from the date of delivery under normal use and conditions Defective Product under warranty shall be at Xtramus Technologies discretion repaired or replaced To the extent permitted by app...

Страница 3: ...2 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNOLOGIES REVISION HISTORY Date FW Version FPGA Version USM Version History Feb 2009 1 0 First version ...

Страница 4: ...9 3 1 Choice of UTP Cable and Optical fiber 9 3 1 1 10GBASE T Copper Wire 9 3 1 2 10GBASE R Optical Fiber 10 3 2 Connection of UTP Cable and Optical fiber 11 3 2 1 10GBASE T Copper Wire 11 3 2 2 10GBASE R Optical Fiber 11 3 3 Application for your network 14 3 3 1 Application for University 14 3 3 2 Application for Online Game Company 15 3 3 3 Application for Home User 16 4 Additional Function 18 4...

Страница 5: ...e Using fiber as the media still dominates transmission of long distance How will you configure network between these two media Here comes the XG2 for the best solution XG2 is a media converter for connection between 10GBASE R and 10GBASE T For example administrator of ISP can has FTTx service from Central Office to the user s street or large organization building by fiber Without extra equipment ...

Страница 6: ...Gbps Ethernet over a 1310 nm wavelength connection on single mode fiber via IEEE 802 3 Clause 49 64B 66B Physical Coding Sub layer PCS using a line rate of 10 3125 Link ACT status Display the Network linked active status Loopback status Indicate the Loopback test status of A and B ports Loopback test is the method to send out signal and quickly back to the same source entity to test the transmissi...

Страница 7: ...pearance 2 1 Front and Rear Side There are holes with fan for ventilation 2 2 Top side As the graph above the name plate of XG2 2 3 Right side Right side has ports that connect with physical transmission media Ventilation Hole 10G Base T Port Status LED SFP Transceiver Port FAN ...

Страница 8: ...ansceiver Status SFP OFF No SFP transceiver connector is plugged Green Connector of LR Transceiver is plugged 10BASE R Mode LR Note 1 Amber Connector of SR Transceiver is plugged ON Green Display the Network linked Active status ON at Port A connection of network cable at port A is linked ON at Port B connection of optical fiber at port B is linked OFF No connection Connection Status Link ACT A B ...

Страница 9: ...ication Power Socket 12V DC Plug power from DC 12V adapter Note XG2 media converter has to convert and transmit data flow for both copper and fiber connection that has larger power consumption Please do use the power adapter that comes with XG2 to prevent damage LED Status Type Label Description Power Status Power LED is ON when power jack of adapter is plugged Console Port Power LED Power Socket ...

Страница 10: ...elect which speed to use Connectors 10GBASE T uses 650 MHz versions of the venerable IEC 60603 7 8P8C RJ 45 connectors that is already widely used in Ethernet Cables 10GBASE T works up to 55 m 180 ft with existing Category 6 cabling In order to allow deployment at the usual 100 m 330 ft the standard uses a new partitioned Category 6a cable specification designed to reduce crosstalk between UTP cab...

Страница 11: ...rt distances over deployed multi mode fiber cabling it has a range of between 26 meters 85 ft and 82 meters 270 ft depending on cable type It also supports 300 meters 980 ft operation over new 50 µm 2000 MHz km OM3 multi mode fiber MMF The transmitter can be implemented with a VCSEL Vertical Cavity Surface Emitting Laser which is low cost and low power MMF has the advantage of having lower cost co...

Страница 12: ...ave a larger core diameter and are used for short distance communication links and for applications where high power must be transmitted Single mode fibers are used for most communication links longer than 200 meters Fiber Buffer Jacket color Meaning Yellow Single mode optical fiber long distance connection Orange Multi mode optical fiber short distance connection 3 2 Connection of UTP Cable and O...

Страница 13: ...ke RJ 45 connector that there is no component inside at all SFP Transceiver is an active component that consumes power from XG2 and it has the key function that convert signals between optical data flow and electronic data flow A Handgrip to remove module from XG2 easily B Connection from LC fiber connector that is described above C Bottom of the transceiver module D Electronic conductor to XG2 bo...

Страница 14: ...o powered fiber is connected Amber Amber SR mode SFP form factor transceiver connector is plugged No powered fiber is connected Green Green LR mode SFP form factor transceiver connector is plugged Powerd fiber is connected Green Amber SR mode SFP form factor transceiver connector is plugged Powerd fiber is connected The size and specification of transceiver are independent from the Ethernet protoc...

Страница 15: ...tical fiber with 10BASE LR mode which can extend the distance beyond several tenth of kilometer C XG2 is located at the computer center of university D After the conversion of XG2 expensive equipment for transmitting receiving network data via optical fiber is not required afterward E Full 10Gbps Ethernet Switch may beyond your budget or it is not available Some 1Gbps Switch reserves a swappable s...

Страница 16: ...company might be long so construct the connection via single mode optical fiber with 10BASE LR mode which can extend the distance beyond several tenth of kilometer D XG2 is located at the control room of the game company E After the conversion of XG2 transceiver and equipment of optical fiber is not required in the control room afterward F Depending on the requirement of loading Ethernet Switch wi...

Страница 17: ... Fiber to the building FTTB Fiber to the home FTTH The building on the left is the central office the building on the right is one of the buildings served by the central office The white or gray blocks represent separate rooms or office spaces within the same building A Central Office of ISP B Network connection via optical fiber C Installation of XG2 for media conversion D Network connection via ...

Страница 18: ...ame location and distributes the connection by Gigabit switch or media converter to copper wired destination Depends on the bandwidth required for client ISP can configure a XG2 media converter between the connection of light blue and dark blue line in the graph With 10G Ethernet conversion between fiber and copper wire ISP can provide heavyweight bandwidth service that is closer to the client wit...

Страница 19: ...2 flows returns to their source entity Here it illustrates how loopback works A XG2 that loopback function is enable for other test equipment or network infrastructure B Signal with test patterns such as BERT is sent D Signal with test patterns is back to original entity test equipment C Network equipment or test equipment with 10GBASE T port that is able to send test patterns with destination of ...

Страница 20: ...All programs Æ Accessories Æ Communications Æ Hyper Terminal Æ Input a name for this connection such as XG2 and also select an icon for this connection Select the COM port of PC for this connection Generally it is COM1 Configure the parameter of COM port as below 38400 8 None 1 None ...

Страница 21: ...put 2 to disable Line Loopback Input 3 the console shows the network cable length from this XG2 to the 10GBase T Ethernet Switch Connect cable before reading the message Input 4 the console shows the twist pair and polarity of the connection from 10GBase T Ethernet Switch XG2 swaps twist pair and polarity automatically and the information here is for reference Connect cable before reading the mess...

Страница 22: ...not required in most of case Please locate it at good ventilation place with suitable temperature and humility is required Temperature Operating 0 40 32 104 Storage 0 50 32 122 Humidity Operating 0 85 RH Storage 0 85 RH The XG2 is an Ethernet media converter that complies with related IEEE standard so system update at customer s side is not required ...