Xtramus LES-5160 Скачать руководство пользователя страница 1

   

 

 

 

 

LES-5160 

Cat-5e Simulator 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

USM Ver 1.2

 

Содержание LES-5160

Страница 1: ...LES 5160 Cat 5e Simulator USM Ver 1 2 ...

Страница 2: ...accurate and reliable However Xtramus Technologies assumes no responsibility or liability for any errors or inaccuracies that may appear in the document Trademarks LES 5160 is a trademark or registered trademark of Xtramus Technologies All other trademarks and registered trademarks are the property of their respective owners Warranty Xtramus Technologies warrants for the hardware provided along wi...

Страница 3: ...te Version History 2014 07 23 1 0 First version 2014 12 03 1 1 Add the description of the three length simulation modes 2019 05 05 1 2 1 Change header and footer pictures 2 Modify the description about cable length setting ...

Страница 4: ...e Installation 18 2 2 1 Bracket installation 18 2 2 2 Modules Installation 20 2 2 3 Power Module 22 2 2 4 Fan Module 23 3 LES 5160 Management 24 3 1 Managing LES 5160 with Management Webpage 24 3 1 1 Accessing LES 5160 Management Webpage 25 3 1 1 1 Access with IP address 25 3 1 1 2 Access with UPnP service 25 3 1 3 LES 5160 Management Webpage System 28 3 1 3 1 System Information 28 3 1 3 2 Module ...

Страница 5: ...e protocols such as 10Base T 100BASE TX and 1000BASE T thus making your network verification system more complete All XLE series modules are equipped with real time LEDs which display the status of the system and the simulating cable length thus allowing users to view network status easily LES 5160 cable length simulator provides an easy to access Management Webpage allowing users to view system s...

Страница 6: ... Advantages Provide the network environments under various cable lengths saving the cable deploying work in practical Provide reliable long distance connection Provide cable simulation function of a very long distance saving plenty of space for placing the real cables Web management Main Applications Test for different cable length simulations in laboratories Test for multiple DUTs with long cable...

Страница 7: ... for installation of modules Each module card provides the simulation of one cable Cat 5e line Besides the Front Part provides 3 slots for installing the fan module CASC module and management module Please see 1 3 2 LES 5160 Front Part for more information Back Part LES 5160 s back part includes 3 different slots Please see 1 3 4 LES 5160 Back Part for more detailed information ...

Страница 8: ...installed in LES 5160 chassis with 1 management port for accessing the Management Webpage and 1 console port for accessing the terminal settings XLE CASC It is a module pre installed in LES 5160 with 2 ports where each port can connect another LES 5160 providing simultaneous access to the Management Webpage Cable Cat 5e simulation module Cable Cat 5e simulation modules can be inserted in slot 2 17...

Страница 9: ...e ventilation for the LES 5160 chassis XLE M667 Allow users to view counters perform system maintenance XLE CASC Cascade multiple LES 5160 chassis Cat 5e Simulation Modules XLE C5E Modules for Cat 5e simulation These Cat 5e simulation modules can be installed in slot 2 17 and support hot swap Please see the sections down below for more detailed information regarding to LES 5160 modules ...

Страница 10: ...is Interface Ports CTRL PWR Reserved for future use PWR Reserved for future use LED Power Green ON XLE SFAN is power on Green OFF XLE SFAN is power off Sys Green ON XLE SFAN is powering up properly Green OFF XLE SFAN is power off Status 0 Reserved for future use Status 1 Reserved for future use Note XLE SFAN does not support hot swap Please do not draw the XLE SFAN module out of the LES 5160 chass...

Страница 11: ...ck to RS232 cable between your PC and the Console Port of LES 5160 Interface Ports Console Port One 2 5mm Phone Jack Port for managing LES 5160 via serial port Management Port One 10 100M RJ45 Port for managing LES 5160 via management webpage LED Power Green ON XLE M667 is power on Green OFF XLE M667 is power off Sys Yellow ON XLE M667 is booting and preparing for test Green ON Blinking XLE M667 i...

Страница 12: ...he Up port or Down port of the chassis with the RJ45 cables For the cascaded chassis you can manage all the chassis through one integrated web page Interface Ports Port Up One 10 100M RJ45 Port for cascading another LES 5160 chassis Port Down One 10 100M RJ45 Port for cascading another LES 5160 chassis LED Power Green ON LES 5160 is powered on Green OFF LES 5160 is powered off Note XLE CASC does n...

Страница 13: ...SE T LED Status Pwr Green ON XLE C5E is powered on Green OFF XLE C5E is powered off 1m Green ON XLE C5E is booting properly and is ready for tests Yellow ON Error occurred when booting XLE 7S81 100m Green ON Port A B is connected Green Blinking Port A B is transmitting receiving data Reserved for future use Reserved for future use Note All LEDS will be off when upgrading FPGA Firmware ...

Страница 14: ...LES 5160 s back part includes 3 different slots for installing the DC module AC module and Fan module LES 5160 Back Part Description XLE RFAN It is a fan module pre installed in the back part of LES 5160 chassis XCP A1W 300 It is a power module based on AC power source ...

Страница 15: ...XLE RFAN consists of two fans as shown in the picture below After installing XLE RFAN the Management Web Page will show the operation of XLE RFAN please see the 3 1 4 LES 5160 Management Webpage Management for more information ...

Страница 16: ... providing power source of 300W AC Redundant SPS Vin 90 240VAC The Power Jack of XCP A1W 300 is a Male IEC 320 Receptacle To activate XCP A1W 300 XLEP AC 100 just turn on off the O I button after connecting a power source cable in Male IEC 320 Receptacle ...

Страница 17: ...proper physical media and applications in your network environment is crucial when installing LES 5160 Besides using the proper method for installing Cat 5e simulation modules into LES 5160 slots is also crucial Please see the sections down below for detailed information regarding to physical media types LES 5160 application and the proper method for installing a Cat 5e simulation module 2 1 Choic...

Страница 18: ...better understanding on how to install the hardware of LES 5160 2 2 1 Bracket installation Steps for installing a Bracket in LES 5160 First of all you must have an Empty Slot for the Installation of a Bracket Attach the Bracket s Latch on the internal face of Chassis Latch ...

Страница 19: ...0 After attaching the Bracket s Latch on the internal face of Chassis Latch let this point be a fix central rotation point and push the bottom part of Bracket into LES 5160 Lock the Captive Screw into the LES 5160 to fix the Bracket into LES 5160 ...

Страница 20: ...E module in LES 5160 Aim the border side of a Cat 5e simulation module with the LES 5160 internal slide road and push this module into LES 5160 Please make sure if the XLE C5E module is well fixed into LES 5160 by pushing the bracket of the module into LES 5160 ...

Страница 21: ...21 Steps for installing a XLE C5E module in LES 5160 Lock the Captive Screw into the LES 5160 to fix the module into LES 5160 ...

Страница 22: ...the Power Module into the respective slot of LES 5160 and push the handle of the Power Module into the slot After the Bracket of the Power Module reaches the LES 5160 lock the captive screw into LES 5160 as shown by arrows 4 and 5 Note The XCP A1W 300 doesn t support hot swap Please don t remove Power Module during System operation ...

Страница 23: ... and shall be installed on the Fan slot located on the far left side of LES 5160 chassis This module card provides ventilation for the LES 5160 chassis Warning The CTRL PWR port and PWR port are preserved for future use Please do not conduct any cable connections or LES 5160 may be seriously damaged ...

Страница 24: ... Managing LES 5160 with Management Webpage Before accessing to LES 5160 s management webpage please connect the network interfaces between the PC and the manage card XLE M667 and configure the IP address for LES 5160 Please refer to the picture down below to configure the IP address The default IP address is 192 168 1 8 ...

Страница 25: ...ws windows XP windows7 or versions above It is very convenient if you forget the IP address you ve set or under the condition of not connecting to the console Access the LES 5160 s management webpage through the UPnP service Click Computer manage to enter the Computer Management interface Click Services and Applications Services then the available services will be listed in the middle pane Ensure ...

Страница 26: ...6 Go to Network You can see the LES 5160 device is listed If you cannot see the LES 5160 please turn off your firewall and then try again Double click the icon of LES 5160 to enter the management webpage ...

Страница 27: ...tting Options contains options for LES 5160 settings information and statistics which can be divided into System You can view system information here in this field Management This option allows you to view the chassis status characteristic curves and set the cable length Maintenance This option allows you to upgrade the firmware save the settings and reset to factory defaults D Main Display Screen...

Страница 28: ...s by click the links at the upper left corner 3 1 3 1 System Information System Information displays LES 5160 system information including System Information Model Name The model of the device LES 5160 Serial Number LES 5160 s serial number MAC Address LES 5160 s MAC address Hardware version PCB Version of XLE M667 Firmware Version LES 5160 s current firmware version IP Status ...

Страница 29: ...IP address Subnet Mask LES 5160 s subnet mask Gateway IP LES 5160 s gateway address 3 1 3 2 Module Information This screen displays the detailed information of the module including the slot number module name firmware version firmware date serial number and MAC address 3 1 3 3 IP settings IP Settings Allows you to set how LES 5160 will acquire its IP subnet mask and gateway addresses Also you coul...

Страница 30: ...fields down below DHCP LES 5160 acquires its IP subnet mask and gateway addresses automatically from network s DHCP server Address You can input LES 5160 s IP address here in this field Subnet Mask You can input LES 5160 s subnet mask here in this field Gateway You can input LES 5160 s gateway address here in this field Apply Apply the changes you ve made here Note1 The default IP address for LES ...

Страница 31: ... length settings The page is shown as follows Chassis Overview A Name of the module B Display the operation status of each module and cable length settings C Display the communication status of the modules when the module is initiating the RJ45 ports are brown indicating the module is establishing communication with the management card and after that the RJ45 ports will be green Now the module is ...

Страница 32: ...settings here effective 3 1 4 3 Characteristic Chart This page is used to view the characteristic chart of a certain module The page is shown as follows Slot ID select the slot ID of the module to see its characteristic chart Line select the wire pairs There are four pairs Pair 12 Pair 36 Pair 45 and Pair 78 and you can also choose to display all the four pairs All Pair In the chart the x axis den...

Страница 33: ...the Browse button to choose the firmware file you would like to upgrade LES 5160 s firmware files are in the format of bin Apply Click this button to start upgrading LES 5160 s firmware b Single Subcard This mode is to upgrade the firmware of a single XLE C5E module Single Subcard Slot ID Click the scroll down menu to select the module you want to upgrade firmware on Browse Click the Browse button...

Страница 34: ...S 5160 s firmware files are in the format of bin Apply Click this button to start upgrading LES 5160 s firmware And then the firmware of the selected modules will be upgraded in sequence 3 1 5 2 Save Changes Save Changes Save If you don t save the settings you ve made via LES 5160 s management webpage all settings will be erased after rebooting LES 5160 Click the Save button to save the settings t...

Страница 35: ...tore You can set all LES 5160 s settings to default by clicking the Restore button 3 1 5 4 System Reboot System Reboot Reboot You can reboot LES 5160 by clicking the Reboot button Please note that all unsaved settings will be lost after system reboot ...

Страница 36: ...ng XLE Series Modules Dimension 441 mm x 310 mm x 88 mm Temperature Operating 0o C 40o C 32o F 104o F Storage 0o C 50o C 32o F 122o F Humidity non condensing Operating 0 85 RH Storage 0 85 RH Built in Sensors Detecting system temperatures rotation speed of fans and system voltage ...

Отзывы: