7
3
Specifications
Supply Voltage
18 to 30 VDC
Power Consumption
5.4 W during normal operation, 5.9 W with alarm on
Current Consumption
225 mA at 24 VDC normal operation, 245 mA with alarm on
Fuse Rating
1.6A
Dimensions (WHD)
225 mm x 225 mm x 85 mm (8 7/8” x 8 7/8”x 3 3/8”)
Weight
1.9kg (4.2 lbs)
Operating Conditions
(To operate the VLC detector outside
these parameters please contact
your nearest Xtralis Office)
l
Ambient:
0°C to 39°C (32°F to 103°F)*
l
Tested:
-10°C to +55°C (14°F to 131°F)
l
Sampled Air:
-20° to 60° C (-4° to 140° F)
l
Humidity:
10-95% RH, non-condensing
Storage Conditions
(Non-operational)
l
Battery life:
up to 2 years
l
Humidity:
dry (<95%)
l
Temperature:
0° to 85° C,
l
Must not exposed to sunlight or other radiation sources
Sampling Pipe Network
l
Maximum area of coverage:
800 m² (8000 sq. ft.)
l
Maximum Single Pipe Length:
80 m (max. 20 holes)
l
Maximum branched (2) Pipe Lengths:
50 m each (max. 20 holes)
l
Computer Design Tool:
ASPIRE2
Pipe Size
l
ID:
15-21 mm (0.874 in)
l
OD:
25 mm (1.050 in.)
Relays
3 relays, contacts rated 2A @ 30 VDC
Programmable to latched or non-latched states
Relays Default Configuration
l
Fire
l
Pre-Alarm
l
Alert/Fault (Maintenance and Isolate)
l
Programmable 0 - 60 sec. time delay for each relay
IP Rating
IP30
Cable Access
4 x 25 mm (1 in) cable entries
Cable Termination
Screw terminal blocks (0.2-2.5 sq mm, 30-12 AWG)
Detector Resolution
0.005 to 20.00% obs/m (0.0015 to 6.25% obs/ft.)
Threshold Setting Range
l
Alert:
0.005 - 1.990% obs/m (0.0015 - 0.6218% obs/ft.)
l
Pre-Alarm:
0.010 -1.995% obs/m (0.0031 - 0.6234% obs/ft.)
l
Fire:
0.015 - 20% obs/m (0.0046 - 6.25% obs/ft.) **
Key Software Features
l
Event log: Up to 12000 events stored on FIFO basis.
l
(Volatile Event Log) Smoke level, alarms and faults with time and date
stamp
l
AutoLearn: Minimum 15 minutes, maximum 15 days. (Recommended
minimum period 1 day).
l
During AutoLearn thresholds are NOT changed from pre-set values.
Table 3-1: VESDA VLC detector specifications
* Product UL listed between 0° to 38°C (32° F to 100° F)
** Factory Default = UL268 = Fire set to 12% obs/m (4% obs/ft.) to comply with UL268. If the factory default is off, the
fire threshold can be set up to 20% obs/m (6.25% /ft.)
Содержание VESDA VLC-500
Страница 2: ......
Страница 8: ...VESDA VLC Installation Guide VESDA by Xtralis 2 www xtralis com This page is intentionally left blank ...
Страница 10: ...VESDA VLC Installation Guide VESDA by Xtralis 4 www xtralis com This page is intentionally left blank ...
Страница 12: ...VESDA VLC Installation Guide VESDA by Xtralis 6 www xtralis com This page is intentionally left blank ...
Страница 14: ...VESDA VLC Installation Guide VESDA by Xtralis 8 www xtralis com This page is intentionally left blank ...
Страница 18: ...VESDA VLC Installation Guide VESDA by Xtralis 12 www xtralis com This page is intentionally left blank ...
Страница 28: ...VESDA VLC Installation Guide VESDA by Xtralis 22 www xtralis com This page is intentionally left blank ...
Страница 32: ...VESDA VLC Installation Guide VESDA by Xtralis 26 www xtralis com This page is intentionally left blank ...