10   

UM Temp74 PT100 Vio EN rev.1 19.05.2023 

 

Setup Menu 

 

TEMP:   

Measurement Settings 

 

LOG:   

Data logger settings 

 

SETTINGS: 

General Instrument Settings 

 

 

In measurement mode, press the

 button to enter SETUP mode. 

 

Within the setup, move through the different menus using the

 buttons and press the

 button to access 

the submenu you wish to edit. 

 

Press

 to return to the previous menu and to exit without saving.       

 

 

Temp Settings Menu   

 

 

 

The TEMP Settings menu contains all settings concerning the measurement. 

 

 TEMP: 

 

Measurement Settings 

 

LOG:   

Data logger settings 

 

SETTINGS: 

General Instrument Settings 

 

 

In measurement mode, press

 to enter the SETUP menu. 

 

Press the

 button to access the TEMP SETTINGS menu. 

 

Use

 to select the programme you wish to access. 

The table below shows the Setup menu structure for the parameter, for each programme the options the user can 

choose and the default value: 

Description 

Options 

Factory Settings 

Sensor ID 

Probe 1 - Probe 2 - Probe 3 - Probe 4 

 

Reference probe  Probe 1 - Probe 2 - Probe 3 - Probe 4 

 

Offset 

Probe 1 - Probe 2 - Probe 3 - Probe 4 - Align all   

Calibration Data 

 

 

Resolution 

1 °C - 0.1 °C - 0.01 °C 

0,01 °C 

Stability filter 

Low - Normal - High 

High 

Alarms 

Probe 1 - Probe 2 - Probe 3 - Probe 4 

Deactivated 

Reset 

No - Yes 

No 

 

 

Sensor ID 

 

Access this menu to enter an ID (identification code) to one or more connected channels. 

 

Select which channel you wish to identify. 

 

Starting with the digit with the flashing cursor, enter the desired value using the keys 

 and press 

 to 

move to the next digit. 

 

A code with a maximum length of 10 digits can be entered. 

Note

: If you select a channel with no probe connected, the display will show the error message: "CONNECT THE 

PROBE", accompanied by the icon flashing 

.

 

 

 

 

Содержание Temp74 PT100 Vio

Страница 1: ...INSTRUCTION MANUAL Temp74 PT100...

Страница 2: ...tilingual copy Espa ol Para reducir los gastos este manual ha sido impreso exclusivamente en italiano e ingl s Contacta tu distribuidor para recibir la copia digital multi idioma Deutsch Um umweltfreu...

Страница 3: ...nstrumental Characteristics 6 Technical Data 6 Description Instrument 6 Display single channel 6 Multiview screen 7 Keyboard 7 Key Functions 8 LED 8 Installation 8 Supplied Components 8 Commissioning...

Страница 4: ...ngs 14 Date and time 14 Units of Measurement 14 Language 14 Auto off 14 Sound 14 Password 15 Temperature measurement 15 Measure 15 MAX MIN function 15 HOLD function 15 Other functions 15 Automatic swi...

Страница 5: ...ormation NOTE for useful product information Warning symbols Additional documents providing security information The following documents can provide the operator with additional information to work sa...

Страница 6: ...mended to occasionally clean the instrument casing with a damp cloth and mild detergent This operation should be carried out with the instrument switched off and only by experienced and authorised per...

Страница 7: ...MAX MIN reading Yes Offset Adjustment Yes for each channel independently Internal memory 200 000 data Data logger Manual Automatic Programmed Sampling 1 min 99 hours Working conditions Temperature 0 6...

Страница 8: ...X and MIN values recorded Press for 3 seconds to activate and deactivate the HOLD function and to deactivate the MAX MIN recording function if active Directional key DOWN RM to scroll through menus an...

Страница 9: ...he display brightness Only at this point do the buttons regain their function LED All instruments are equipped with a two colour LED red and green that provides the user with important information on...

Страница 10: ...carrying case Only use the original carrying case to transport the instrument Contact your local distributor if you need to buy it back The inside of the case is shaped to accommodate the instrument...

Страница 11: ...e below shows the Setup menu structure for the parameter for each programme the options the user can choose and the default value Description Options Factory Settings Sensor ID Probe 1 Probe 2 Probe 3...

Страница 12: ...annels to be aligned to the reference channel Select our reference channel from the Setup menu Temp Settings Reference Probe and press to confirm In the Offset Probes menu select Align All The measure...

Страница 13: ...the table above Note When the reset is complete the instrument returns to measurement mode and the parameters are reset to default settings Log Settings Menu TEMP Measurement Settings LOG Data logger...

Страница 14: ...pendently once the set date and time is reached and will stop Note If recording takes place while there is a single channel measurement on the display data concerning only that channel will be saved I...

Страница 15: ...er battery life Brightness Access this Setup menu to choose between three different display brightness levels Low Normal High Note Keeping the display at high brightness at all times negatively affect...

Страница 16: ...appears on the display Always wait for the measurement to become stable Note If no temperature probe is connected the message CONNECT A PROBE appears When connecting or disconnecting probes the instru...

Страница 17: ...corrected and the adjustment value with flashing cursor using the keys correct the value to Current Temperature to 0 0 C press to confirm and record the adjustment Note The adjustment affects the ent...

Страница 18: ...e manufacturer will repair or replace defective components This guarantee applies only to the electronic part and does not apply if the product has been damaged misused exposed to radiation or corrosi...

Страница 19: ...18 UM Temp74 PT100 Vio EN rev 1 19 05 2023 XS Instruments Via della Meccanica n 25 41012 Carpi MO ITALY Tel 39059 653274 Fax...

Отзывы: