Counter Function 
 

Set one of these units: PCS, % or 

, and press 

 button. 

Display shows “

S

 – 5

”: 5 is the number of required pieces for the sampling, or the % to associate with the reference sample. 

With the 

 button, select the desired value between these: 5, 10,50, 100, 500 e 1000. 

Place samples on the plate and press 

 button. 

Now It is ready for count all your samples.  
 

RS-232 Settings 

 

Connect the Rs-232 printe on the backside of the scale.  

Keep pressed 

 button for 3 seconds, the display shows first “

rS—Set

”,  

8888888

.

.  

According with the following table, set the correct values: 

 

 

 

0

= 9600 

1

= 19200 

--- 

--- 

0

= print in continuos 

1

= print when stable 

2

= press           to print  --- 

0

= --- 

1

= print the date 

--- 

--- 

0

= --- 

1

= print the item * 

--- 

--- 

0

= PC Mode 

1

= special paper 

2

= continuos paper 

3

= micro-printer 

--- 

--- 

--- 

--- 

--- 

--- 

 

Confirm with  

 button. 

 
Item settings 

 
Is possible to set an “Item”, that will be printed with the other values, for example the serial number.To do that, keep 

pressed 

 button for 3 seconds. Display shows first “

ItemSet

”, than “1234567”. Modify the string using following key:  

 

  

 set the value, 

 

  

 switch to next value   

 

  

 confirm. 

8888888 

(a) (b) (c)  (d)  (e)  (f)  (g) 

 

 

  

 modify the value, 

 

    

 switch to the next position   

 

Содержание BL 2002

Страница 1: ...User Manual BL 303 BL 602 BL 2002 BL 3001 BL 6001 BL 30K1 Models ...

Страница 2: ...6 START 7 DATE AND TIME SETTINGS 7 USER CALIBRATION 7 CALIBRATION PROCEDURE 7 UNIT SETTING 8 UNIT SELECTION 8 DEFAULT UNIT SETTINGS 8 ZERO 8 TARE 8 MEASURE 8 COUNTER FUNCTION 9 RS 232 SETTINGS 9 ITEM SETTINGS 9 BATTERY 10 TROUBLESHOOTING 10 DATASHEETS 10 DISPOSAL OF ELECTRONIC DEVICES 11 ...

Страница 3: ...3 Glass protection BL 303 ...

Страница 4: ...4 BL 602 1 2 3 4 5 6 7 8 ...

Страница 5: ...5 BL 2002 BL 3001 BL 6001 ...

Страница 6: ...C Working Humidity 40 85 Installation and removal of the scale must be done with the machine switched off Do not use the scale upside down After switch On wait at least 30 minutes warming up before the first weighing For assistance contact your dealer or an authorized service center Keyboard On Off Hold for 3 seconds to start Calibration procedure Unit selection Print data RS 232 printer PC Tare Z...

Страница 7: ...he value scroll to the next value confirm Successively are required 1 Month Month 2 Day Day 3 Hour Hour 4 Minute Min User Calibration Each balance is calibrated in the laboratory by technicians using certified sample masses Provided with all models there is a sample mass useful to test the functionality of the instrument Calibration procedure o Turn on the balance and wait at least 30 min of warmu...

Страница 8: ...With no weight on the scales press the button to take the 0 00 reading on the display The ZERO function is only effective if the value shown is less than 4 of total capacity If the value is greater than 4 the load is regarded as a tare Tare After placing the tare on the scales press the button to reset the value displayed to 0 00 The load used for Tara has to be subtracted by the overall capacity ...

Страница 9: ...the display shows first rS Set 8888888 According with the following table set the correct values a 0 9600 1 19200 b 0 print in continuos 1 print when stable 2 press to print c 0 1 print the date d 0 1 print the item e 0 PC Mode 1 special paper 2 continuos paper 3 micro printer f 0 g 0 Confirm with button Item settings Is possible to set an Item that will be printed with the other values for exampl...

Страница 10: ...rument in correspondence of the load cell Datasheets Models BL 303 BL 602 BL 2002 BL 3001 BL 6001 BL 30K1 Cod 27000513 27000323 27000313 27000113 27000123 27000133 Capacity 300 g 600 g 2000 g 3000 g 6000 g 30 000 g Division 0 001 g 0 01 g 0 01 g 0 1 g 0 1 g 0 1 g Repeatability 0 001 g 0 01 g 0 01 g 0 1 g 0 1 g 0 2 g Linearity 0 003 0 03 0 02 0 2 0 2 0 2 Sensor Strain gage Strain gage Strain gage S...

Страница 11: ...d of in public landfills According to the UE Directive 2002 96 EC the European users of electrical and electronic equipment can return it to the dealer or manufacturer upon purchase of a new one The illegal disposal of electrical and electronic equipment is punished with an administrative fine Ver 1 0_ENG_21 04 2015 ...

Отзывы: