background image

5  

 

UM Termometri serie 7Vio ENG rev.0 14.04.2021

 

 

 Additional documents providing safety information

 

The  following  documents  can  provide  the  operator  with  additional  information  to  work  with  the 
measuring system safely:

 

 

specific notes on product safety.

 

 

 

Use according to destination                                                                 

 

This instrument is designed exclusively for temperature measurements both in the laboratory and directly 
in the field. 

 

Pay attention to the technical specifications shown in the INSTRUMENT FEATURES / TECHNICAL DATA table; 
any other use is to be considered unauthorized.

 

This instrument has left the factory in perfect technical and safety conditions.

 

The  regular  functionality  of  the  device  and  the  operator  safety  are  guaranteed  only  if  all  the  normal 
laboratory safety standards are respected and if all the specific safety measures described in this manual 
are observed.

 

 

 

Basic requirement for safe use 

 

The  regular  functionality  of  the  device  and  the  operator  safety  are  guaranteed  only  if  all  the  following 
indications are respected:

 

 

the instrument can be used in accordance with the specifications mentioned above only;

 

 

the instrument must operate exclusively in the environmental conditions indicated in this manual;

 

•      the only part of the instrument that can be opened by the user is the battery compartment.

 

 Perform other operations only if explicitly authorized by the manufacturer.

 

 

 

 

Unauthorised use 

 

The instrument must not run, if:

 

 

it is visibly damaged (for example due to transportation);

 

 

it has been stored for a long period of time in adverse conditions (exposure to direct light, heat sources 
or  places  saturated  by  gas  or  vapours)  or  in  environments  with  conditions  different  from  those 
mentioned in this manual.

 

 

 

Device maintenance                                                                              

 

If used correctly and in a suitable environment, the instrument does not require maintenance procedures.

 

It is recommended to occasionally clean the instrument case with a damp cloth and a mild detergent.

 

This operation must be performed with the instrument off and by authorized personnel only.

 

The housing is in ABS / PC (acrylonitrile butadiene styrene / polycarbonate). This material is sensitive to 
some organic solvents, for example toluene, xylene and methyl ethyl ketone (MEK).

 

If liquids get into the housing, they could damage the instrument. 

 

Do not open the instrument housing: it does not contain parts that can be maintained, repaired or replaced 
by the user. In case of problems with the instrument, contact your local distributor.

 

It is recommended to use original spare parts only. Contact your local distributor for information. The use 
of non-original spare parts can lead to malfunction or permanent damage to the instrument. Moreover, the 
use of spare parts not guaranteed by the supplier can be dangerous for the user himself.

 

 

 

Responsibility of the instrument owner

 

The person who owns and uses the tool or authorizes its use by other people is the owner of the tool and 
is responsible for the safety of all users of the tool and third parties.

 

The owner of the instrument must inform users of the use of the same safely in their workplace and on the 
management of potential risks, also providing the required protective devices.

 

When using chemicals or solvents, follow the manufacturer's safety data sheets. 

 

 

Содержание 7 Vio

Страница 1: ...USER MANUAL Temp7 PT100 Temp7 K T Temp7 NTC...

Страница 2: ...1 UM Termometri serie 7Vio ENG rev 0 14 04 2021...

Страница 3: ...Features 6 Datasheet 6 Instrument Description 7 Display 7 Keypad 7 LED 8 Setup 8 Supplied component 8 Start up 8 Switching On Off 8 Batteries replacement 8 Instrument transportation 9 Keys Function 9...

Страница 4: ...serie 7Vio ENG rev 0 14 04 2021 Warranty period and limitations 16 Disposal of electrical devices 16 XS Instruments Via della Meccanica n 25 41012 Carpi MO ITALY Tel 39059 653274 Fax 39059653282 www x...

Страница 5: ...ON for a medium risk hazardous situation which could lead to serious injury or death if not avoided ATTENTION for a dangerous situation with reduced risk which can cause material damage data loss or m...

Страница 6: ...ime in adverse conditions exposure to direct light heat sources or places saturated by gas or vapours or in environments with conditions different from those mentioned in this manual Device maintenanc...

Страница 7: ...curacy 2 C 200 100 C 0 2 C 99 9 199 9 C 2 C 200 999 C 0 1 of the read 0 4 C over 150 C 0 25 of the read 1 C below 150 C 0 2 C System Display High definition colours LCD Backlit Brightness setup Manual...

Страница 8: ...uipment ESC key to go back at the measurement mode OK Setup key to confirm the chosen values and enter the Setup from the measurement mode DOWN HOLD key to scroll menus and values in the Setup Short p...

Страница 9: ...witching On Off Turn on the system by pressing the button The display initially activates all segments and then appears model and firmware of the instrument settings related to the most important para...

Страница 10: ...go back to measurement mode Short MAX MIN memory activation MAX value display and MIN value display It is used to scroll and change the parameters of the Setup menu Long Press 3 sec 3 seconds pressure...

Страница 11: ...s and icons Symbols Description Type of probe connected Error in measurement Battery charge indication Measurement stability indicator The bars scroll if the measurement is not stable Press the direct...

Страница 12: ...SETUP mode select the parameter you want to edit by using the directional keys and confirming with Within the selected menu move between the different programs using the directional buttons and press...

Страница 13: ...e temperature probe connected If menu P 7 2 is accessed without a temperature sensor connected the display will show the error message CONNECT THE PROBE accompanied by the flashing icon Note For the T...

Страница 14: ...n three different levels of display brightness LOW low NORMAL medium HIGH high Note Keeping the display bright always adversely affects battery life P9 5 Sleep mode Access this setup menu to select wh...

Страница 15: ...ill flash MIN MAX REC Press the key once to see the maximum value reached up to that moment press it another time to see the minimum value reached up to that moment Pressing again will return the inst...

Страница 16: ...isolate the water ice mixture from the air as much as possible stir for about 10 minutes in this way a temperature of 0 C is reached If the instrument reads 0 0 C measurement chain accuracy then the i...

Страница 17: ...urer will repair or replace defective components This warranty is valid only and exclusively on the electronic parts of the device and does not apply if the product has been damaged used incorrectly e...

Отзывы: